Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RISING CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RISING CORPORATION in KAGMAN, SAIPAN, MP 96950 (NAICS 236115). OSHA activity number 341715332.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rising Corporation — free Get an email when a new federal OSHA severe-injury report for Rising Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
RISING CORPORATION
Site address
KAGMAN
City
SAIPAN
State
MP
ZIP
96950
Mailing
P.O. BOX 10003 PMB 76, SAIPAN, MP 96950
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
7
Ownership type
A

10 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 7 exposed
Issued
Sep 15, 2016
Penalty
Initial $1,312 · Current $918 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:   a) On August 23, 2016, employees were working underneath other employees and head protection was not worn, exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $918.4
  • — Z (S) $1312

1926.304 D

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 15, 2016
Abate by
Sep 27, 2016
Penalty
Initial $2,186 · Current $1,530 Reduced
29 CFR 1926.304(d): Portable, power-driven circular saw(s) were not equipped with a guard above and below the base plate or shoe:   a) On August 23, 2016, a Makita 8" portable circular saw was being operated with the guard disabled, exposing the employees to amputation hazards.
Recent events (2)
  • — I (S) $1530.2
  • — Z (S) $2186

1926.403 B02

Serious Gravity 5 2 instances 7 exposed
Issued
Sep 15, 2016
Abate by
Sep 27, 2016
Penalty
Initial $1,749 · Current $1,224 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    a) On August 23, 2016, a metal gang box designed to be installed and mounted in a wall, was lying on the ground connected to an orange extension cord, exposing employees to electrical hazards.  b) On August 23, 2016, a metal gang box designed to be installed and mounted in a wall, was mounted onto the surface of the 2x4 Leg of a homemade table saw powering a Makita 8" portable circular saw, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $1224.3
  • — Z (S) $1749

1926.405 B01

Serious Gravity 5 3 instances 7 exposed
Issued
Sep 15, 2016
Abate by
Sep 27, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not also effectively closed:   a) On August 23, 2016, near the east side interior of the project, a metal gang box lying on the ground connected to an orange extension cord had unused openings, exposing employees to electrical hazards.   b) On August 23, 2016, near the east side interior of the project, a metal gang box was screwed onto the 2x4 Leg of the homemade table saw powering the Makita 8" portable circular saw had unused openings, exposing employees to electrical hazards.  c) On August 23, 2016, near the east side interior of the project, a metal gang box was screwed onto the 2x4 leg just above the one with the circular saw plugged in had unused openings, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 A02 II C

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 15, 2016
Abate by
Sep 27, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(C): All receptacles used on temporary wiring with a separate equipment grounding conductor were not electrically connected to the grounding conductor:   a) On August 23, 2016, a metal gang box designed to be installed and mounted in a surface wall, was mounted onto the surface of a 2x4 Leg of a homemade table saw  above another gang box that was powering a Makita 8" portable circular saw and the ground wires were not connected between the two metal gang boxes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.404 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 15, 2016
Abate by
Sep 27, 2016
Penalty
Initial $2,186 · Current $1,530 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.   a) On August 23, 2016, at the temporary power source area, the employer did not use either a ground fault circuit interrupters or an assured equipment grounding conductor program to protect employees from electrical hazards.
Recent events (2)
  • — I (S) $1530.2
  • — Z (S) $2186

1926.501 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 15, 2016
Abate by
Sep 27, 2016
Penalty
Initial $2,186 · Current $1,530 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.   a) On August 23, 2016, employees were working on wood beams at heights greater than 6 feet without any fall arrest system, exposing the employees to a fall hazard.
Recent events (2)
  • — I (S) $1530.2
  • — Z (S) $2186

1926.1053 A02

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 15, 2016
Abate by
Sep 27, 2016
Penalty
Initial $1,749 · Current $1,224 Reduced
29 CFR 1926.1053(a)(2): Ladder rungs, cleats, and/or steps were not parallel, level, and uniformly spaced when the ladder was in position for use:   a) On August 23, 2016, a job made ladder was in use that did not have uniformly spaced rungs, exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $1224.3
  • — Z (S) $1749

1926.1053 B13

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 15, 2016
Abate by
Sep 27, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:   a) On August 23, 2016, the top step of a job made step ladder was used and an employee was sitting on the top of the ladder, exposing the employee to a fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.20 B02

Other-than-serious 1 instance 7 exposed
Issued
Sep 15, 2016
Abate by
Sep 27, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.20(b)(2): The employer failed to initiate and maintain programs that provided for frequent and regular inspections of the job sites, materials, and equipment made by competent persons designated by the employer:     a) On August 23, 2016, the supervisor stated they did not inspect the project to determine compliance with safety regulations.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341715332.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.