Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AERONAUTICA WINDPOWER, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AERONAUTICA WINDPOWER, LLC in 35 DORY ROAD, GLOUCESTER, MA 01930 (NAICS 221115). OSHA activity number 341726669.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aeronautica Windpower, LLC — free Get an email when a new federal OSHA severe-injury report for Aeronautica Windpower, LLC is published. One employer, no account, unsubscribe in one click.
Site address
35 DORY ROAD
City
GLOUCESTER
State
MA
ZIP
01930
Mailing
11 RESNIK ROAD, PLYMOUTH, MA 02360
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221115
Employees
3
Ownership type
A

5 citations on file for this inspection.

1910.269 A02 I A

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 18, 2017
Abate by
Jan 24, 2017
Penalty
Initial $5,070 · Current $3,000 Reduced
29 CFR 1910.269(a)(2)(i)(A): Each employee was not trained in, and familiar with, the safety-related work practices, safety procedures, and other safety requirements in this section that pertain to his or her job assignments.    Location: 35 Dory Road, Gloucester, MA:  On or about July 29, 2016, the employer failed to ensure that each employee was trained in, and familiar with, the safety-related work practices, safety procedures, and other safety requirements in this section that pertain to his or her job assignments.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5070

1910.269 A02 I B

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 18, 2017
Abate by
Mar 7, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.269(a)(2)(i)(B): Each employee shall also be trained in and familiar with any other safety practices, including applicable emergency procedures (such as pole-top and manhole rescue), that are not specifically addressed by this section but that are related to his or her work and are necessary for his or her safety.  On or about July 29, 2016, the employer failed to ensure that each employee was trained in, and familiar with, the safety-related work practices for a prompt self-rescue or assisted rescue up tower, and provide the appropriate rescue equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.269 D02 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 18, 2017
Abate by
Jan 24, 2017
Penalty
Initial $5,070 · Current $3,000 Reduced
29 CFR 1910.269(d)(2)(i): The employer shall establish a program consisting of energy control procedures, employee training, and periodic inspections to ensure that, before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up, or release of stored energy could occur and cause injury, the machine or equipment is isolated from the energy source and rendered inoperative.      Location: 35 Dory Road, Gloucester, MA:  On or about July 29, 2016, the employer failed to establish a program for energy control procedures and a program to prevent unexpected energization and start up of the 2.5 MW wind turbine.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5070

1910.269 G02 IV B

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 18, 2017
Abate by
Jan 24, 2017
Penalty
Initial $3,622 · Current $3,000 Reduced
29 CFR 1910.269(g)(2)(iv)(B): Personal fall arrest systems shall be used in accordance with � 1926.502(d).      On or about July 29, 2016, employees did not inspection personal fall arrest equipment prior to use for deficiencies that would require the equipment to be taken out of service, including manufacturer's labels and markings identifying the equipment's use and limitations.     1926.502(d)(21) Personal fall arrest systems shall be inspected prior to each use for wear, damage and other deterioration, and defective components shall be removed from service.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3622

1910.269 L07

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 18, 2017
Penalty
Initial $4,346 · Current $3,000 Reduced
29 CFR 1910.269(l)(7): Conductive articles. When an employee performs work within reaching distance of exposed energized parts of equipment, the employer shall ensure that the employee removes or renders nonconductive all exposed conductive articles, such as key chains or watch chains, rings, or wrist watches or bands, unless such articles do not increase the hazards associated with contact with the energized parts.      Location: 35 Dory Road, Gloucester, MA:  On or about July 29, 2016, the employer failed to ensure that employees remove all exposed conductive articles, such as rings, while working on exposed energized parts.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4346

View Aeronautica Windpower, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341726669.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.