GLOUCESTER, MA —
OSHA Inspection: AERONAUTICA WINDPOWER, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AERONAUTICA WINDPOWER, LLC in 35 DORY ROAD, GLOUCESTER, MA 01930 (NAICS 221115). OSHA activity number 341726669.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AERONAUTICA WINDPOWER, LLC
- Site address
- 35 DORY ROAD
- City
- GLOUCESTER
- State
- MA
- ZIP
- 01930
- Mailing
- 11 RESNIK ROAD, PLYMOUTH, MA 02360
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221115
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.269 A02 I A
- Issued
- Jan 18, 2017
- Abate by
- Jan 24, 2017
- Penalty
- Initial $5,070 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.269(a)(2)(i)(A): Each employee was not trained in, and familiar with, the safety-related work practices, safety procedures, and other safety requirements in this section that pertain to his or her job assignments. Location: 35 Dory Road, Gloucester, MA: On or about July 29, 2016, the employer failed to ensure that each employee was trained in, and familiar with, the safety-related work practices, safety procedures, and other safety requirements in this section that pertain to his or her job assignments.
Recent events (2)
- — I (S) $3000
- — Z (S) $5070
1910.269 A02 I B
- Issued
- Jan 18, 2017
- Abate by
- Mar 7, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.269(a)(2)(i)(B): Each employee shall also be trained in and familiar with any other safety practices, including applicable emergency procedures (such as pole-top and manhole rescue), that are not specifically addressed by this section but that are related to his or her work and are necessary for his or her safety. On or about July 29, 2016, the employer failed to ensure that each employee was trained in, and familiar with, the safety-related work practices for a prompt self-rescue or assisted rescue up tower, and provide the appropriate rescue equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.269 D02 I
- Issued
- Jan 18, 2017
- Abate by
- Jan 24, 2017
- Penalty
- Initial $5,070 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.269(d)(2)(i): The employer shall establish a program consisting of energy control procedures, employee training, and periodic inspections to ensure that, before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up, or release of stored energy could occur and cause injury, the machine or equipment is isolated from the energy source and rendered inoperative. Location: 35 Dory Road, Gloucester, MA: On or about July 29, 2016, the employer failed to establish a program for energy control procedures and a program to prevent unexpected energization and start up of the 2.5 MW wind turbine.
Recent events (2)
- — I (S) $3000
- — Z (S) $5070
1910.269 G02 IV B
- Issued
- Jan 18, 2017
- Abate by
- Jan 24, 2017
- Penalty
- Initial $3,622 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.269(g)(2)(iv)(B): Personal fall arrest systems shall be used in accordance with � 1926.502(d). On or about July 29, 2016, employees did not inspection personal fall arrest equipment prior to use for deficiencies that would require the equipment to be taken out of service, including manufacturer's labels and markings identifying the equipment's use and limitations. 1926.502(d)(21) Personal fall arrest systems shall be inspected prior to each use for wear, damage and other deterioration, and defective components shall be removed from service.
Recent events (2)
- — I (S) $3000
- — Z (S) $3622
1910.269 L07
- Issued
- Jan 18, 2017
- Penalty
- Initial $4,346 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.269(l)(7): Conductive articles. When an employee performs work within reaching distance of exposed energized parts of equipment, the employer shall ensure that the employee removes or renders nonconductive all exposed conductive articles, such as key chains or watch chains, rings, or wrist watches or bands, unless such articles do not increase the hazards associated with contact with the energized parts. Location: 35 Dory Road, Gloucester, MA: On or about July 29, 2016, the employer failed to ensure that employees remove all exposed conductive articles, such as rings, while working on exposed energized parts.
Recent events (2)
- — I (S) $3000
- — Z (S) $4346
More inspections at Aeronautica Windpower, LLC
View Aeronautica Windpower, LLC's full OSHA safety record →
More inspections in this industry (NAICS 221115)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341726669.