Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ATLAS BOLT & SCREW COMPANY LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ATLAS BOLT & SCREW COMPANY LLC in 1628 TROY RD, ASHLAND, OH 44805 (NAICS 332722). OSHA activity number 341738862.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atlas Bolt & Screw Company LLC — free Get an email when a new federal OSHA severe-injury report for Atlas Bolt & Screw Company LLC is published. One employer, no account, unsubscribe in one click.
Site address
1628 TROY RD
City
ASHLAND
State
OH
ZIP
44805
Mailing
1628 TROY RD, ASHLAND, OH 44805
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332722
Employees
60
Ownership type
A

2 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 2, 2016
Abate by
Jan 5, 2017
Penalty
Initial $12,346 · Current $6,173 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):     a.)    Atlas Bolt and Screw Company, LLC located at 1628 Troy Rd. Ashland, OH; The employer did not ensure employees were protected while operating the pneumatic Hammer in the Zinc Mold Department . Employees are required to operate the hammer and are exposed to crush hazards in that the point of operation is not adequately guarded.
Recent events (2)
  • — I (S) $6173
  • — Z (S) $12346

1910.147 D03

Repeat Gravity 10 1 instance 4 exposed
Issued
Dec 2, 2016
Abate by
Jan 5, 2017
Penalty
Initial $24,693 · Current $12,346 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):     a.)    Atlas Bolt and Screw Company, LLC located at 1628 Troy Rd. Ashland, OH; The employer did not ensure employees were protected while operating the pneumatic Hammer in the Zinc Mold Department. On August 22, 2016, an employee attempted to clear a puck jam inside the hammer when another employee cycled the machine, resulting in a partial finger amputation.    Atlas Bolt & Screw Company, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(d)(3) which was contained in OSHA inspection number 740161, citation number 1, item number 3 and was affirmed as a final order on 3/21/13, with respect to a workplace located at 1628 Troy Rd. Ashland, OH 44805.