OSHA Inspection: NCI GROUP INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NCI GROUP INC. in 1011 ELLISON AVE, OMAHA, NE 68110 (NAICS 332322). OSHA activity number 341739332.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NCI Group INC. — free Get an email when a new federal OSHA severe-injury report for NCI Group INC. is published. One employer, no account, unsubscribe in one click.
Establishment
NCI GROUP INC.
Site address
1011 ELLISON AVE
City
OMAHA
State
NE
ZIP
68110
Mailing
1011 ELLISON AVE, OMAHA, NE 68110
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
40
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 2 instances 4 exposed
Issued
Jan 17, 2017
Abate by
Feb 10, 2017
Penalty
Initial $12,675 · Current $7,605 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    The employer is failing to protect employee(s) from caught in hazards at the facility.  This was most recently documented on September 21, 2016 at 1011 Ellison Ave Omaha, NE 68110.  This hazard(s) observed in the following but not limited to:    a. The Soffit Shear located on the South Wall of the facility had an opening in the existing shroud/guard of 8 inches that allowed for a person to be able to reach into point of operation.    b. On or about August 24, 2016 an employee's thumb was amputated when reaching for a tape measure located adjacent to a pinch point of the shear.  At the time of the incident a guard had been removed exposing the pinch point.  This pinch point in conjunction with the sharp edge of the tape measure caused the amputation.
Recent events (2)
  • — I (S) $7605
  • — Z (S) $12675

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 17, 2017
Abate by
Feb 10, 2017
Penalty
Initial $9,959 · Current $5,975 Reduced
29 CFR 1910.219(d)(1):     Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    The employer is failing to protect employee(s) from a caught in hazard.  This was most recently observed on September 21, 2016 at 1011 Ellison Ave. Omaha Nebraska.  The guard for the drive belt(s) and pulley(s) on the Chicago Press used to making flashing was not equipped with a guard that enclosed the back side of the belt(s) and pulley(s).
Recent events (2)
  • — I (S) $5975
  • — Z (S) $9959

1910.219 E03 I

Serious 1 instance 2 exposed
Issued
Jan 17, 2017
Abate by
Feb 10, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i):     Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B01

Other-than-serious 1 instance 3 exposed
Issued
Jan 17, 2017
Abate by
Feb 10, 2017
Penalty
Initial $7,967 · Current $2,000 Reduced
29 CFR 1910.303(b)(1):     Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:    The employer is failing to protect employees from an electric shock hazard.  This was most recently observed on September 21, 2016  at 1011 Ellson Ave. Omaha Nebraska.  The cord being used to charge the Gene Lift was crushed in several locations and showing exposed conductors and soiled with oil and grease.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $7967

View NCI Group INC.'s full OSHA safety record →