ETTRICK, WI —
OSHA Inspection: PREMIER POWDERCOATING, INC.
Follow-up inspection · Health discipline
At a glance
On , OSHA opened a follow-up health inspection of PREMIER POWDERCOATING, INC. in 15812 BRIDGE ST, ETTRICK, WI 54627 (NAICS 332812). OSHA activity number 341740173.
Where did this inspection happen?
- Establishment
- PREMIER POWDERCOATING, INC.
- Site address
- 15812 BRIDGE ST
- City
- ETTRICK
- State
- WI
- ZIP
- 54627
- Mailing
- PO BOX 95, ETTRICK, WI 54627
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.134 I05 IV
- Issued
- Abate by
- Penalty
- Initial $2613.00 · Current $2613.00
General-duty citation text
29 CFR 1910.134(i)(5)(iv): The employer did not ensure that compressors used to supply breathing air to respirators were constructed and situated so as to have a tag maintained at the compressor containing the most recent change date and the signature of the person authorized by the employer to perform the change: (a) Abrasive Blasting Area; The compressor utilized for supplied breathing air did not have documentation or a tag showing that it was properly maintained for such use.
Recent events (2)
- — P (S) $2613
- — Z (S) $2613
1910.134 I07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both; air supplied was not monitored to prevent carbon monoxide in the breathing air from exceeding 10 ppm: (a) Abrasive Blasting Area; The compressor utilized for supplied breathing air did not have a high-temperature or carbon monoxide alarm to ensure employee(s) wearing the supplied air hood were not overexposed.
Recent events (1)
- — Z (S) $0
More inspections at PREMIER POWDERCOATING, INC.
ETTRICK, WI—2018-02-06 00:00:00
PREMIER POWDERCOATING, INC.
ETTRICK, WI—2015-01-27 00:00:00
PREMIER POWDERCOATING, INC.
ETTRICK, WI—2013-01-09 00:00:00
PREMIER POWDERCOATING INC.
View PREMIER POWDERCOATING, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332812)
COLUMBIA, SC—2026-07-15 00:00:00
77575 - AZZ PRECOAT METALS
COLUMBIA, SC—2026-07-15 00:00:00
77574 - PRECOAT METALS
WICHITA, KS—2026-07-10 00:00:00
DIVERSIFIED SERVICES, INC.
SHARON, PA—2026-07-09 00:00:00
NLMK SHARON COATING, LLC
CUDDY, PA—2026-07-08 00:00:00
SUPERIOR POWDER COATING INC
More inspections in WI
GREEN BAY, WI—2026-07-17 00:00:00
PTS CONTRACTORS, INC.
WAUSAU, WI—2026-07-16 00:00:00
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15 00:00:00
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15 00:00:00
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15 00:00:00
TERONOMY BUILDERS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341740173.