Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of PREMIER POWDERCOATING, INC. in 15812 BRIDGE ST, ETTRICK, WI 54627 (NAICS 332812). OSHA activity number 341740173.

Watch Premier Powdercoating, INC. — free Get an email when a new federal OSHA severe-injury report for Premier Powdercoating, INC. is published. One employer, no account, unsubscribe in one click.
Site address
15812 BRIDGE ST
City
ETTRICK
State
WI
ZIP
54627
Mailing
PO BOX 95, ETTRICK, WI 54627
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
6
Ownership type
A

2 citations on file for this inspection.

1910.134 I05 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2613.00 · Current $2613.00
29 CFR 1910.134(i)(5)(iv): The employer did not ensure that compressors used to supply breathing air to respirators were constructed and situated so as to have a tag maintained at the compressor containing the most recent change date and the signature of the person authorized by the employer to perform the change:  (a) Abrasive Blasting Area; The compressor utilized for supplied breathing air did not have documentation or a tag showing that it was properly maintained for such use.
Recent events (2)
  • — P (S) $2613
  • — Z (S) $2613

1910.134 I07

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both; air supplied was not monitored to prevent carbon monoxide in the breathing air from exceeding 10 ppm:  (a) Abrasive Blasting Area; The compressor utilized for supplied breathing air did not have a high-temperature or carbon monoxide alarm to ensure employee(s) wearing the supplied air hood were not overexposed.