ETTRICK, WI —
OSHA Inspection: PREMIER POWDERCOATING, INC.
Follow-up inspection · Health discipline
At a glance
On , OSHA opened a follow-up health inspection of PREMIER POWDERCOATING, INC. in 15812 BRIDGE ST, ETTRICK, WI 54627 (NAICS 332812). OSHA activity number 342933413.
Where did this inspection happen?
- Establishment
- PREMIER POWDERCOATING, INC.
- Site address
- 15812 BRIDGE ST
- City
- ETTRICK
- State
- WI
- ZIP
- 54627
- Mailing
- PO BOX 95, ETTRICK, WI 54627
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.134 E01
- Issued
- Penalty
- Initial $5543.00 · Current $5543.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Abrasive Blasting Area; The employer does not provided medical evaluations for employee(s) who are required to wear half-mask elastomeric and air supplied hood respirators while abrasive blasting. Premier Powdercoating, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(e)(1), which was contained in OSHA inspection number 1021062, citation number 1, item number 1/C and was affirmed as a final order on July 21, 2015, with respect to a workplace located at 15812 Bridge St. in Ettrick, WI.
Recent events (3)
- — A (R) $5543
- — I (R) $3880
- — Z (R) $5543
1910.94 A04 III
- Issued
- Abate by
- Penalty
- Initial $1109.00 · Current $1109.00
General-duty citation text
29 CFR 1910.94(a)(4)(iii): Air exhausted from blast-cleaning equipment was not discharged through dust collecting equipment: (a) Abrasive Blasting Area; The employer does not require air exhausted from the blast-cleaning equipment to be discharged through dust collecting equipment. Premier Powdercoating, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.94(a)(4)(iii), which was contained in OSHA inspection number 1021062, citation number 2, item number 1 and was affirmed as a final order on July 21, 2015, with respect to a workplace located at 15812 Bridge St. in Ettrick, WI.
Recent events (3)
- — A (R) $1109
- — I (R) $775
- — Z (R) $1109
More inspections at PREMIER POWDERCOATING, INC.
ETTRICK, WI—2016-08-31 00:00:00
PREMIER POWDERCOATING, INC.
ETTRICK, WI—2015-01-27 00:00:00
PREMIER POWDERCOATING, INC.
ETTRICK, WI—2013-01-09 00:00:00
PREMIER POWDERCOATING INC.
View PREMIER POWDERCOATING, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332812)
COLUMBIA, SC—2026-07-15 00:00:00
77575 - AZZ PRECOAT METALS
COLUMBIA, SC—2026-07-15 00:00:00
77574 - PRECOAT METALS
WICHITA, KS—2026-07-10 00:00:00
DIVERSIFIED SERVICES, INC.
SHARON, PA—2026-07-09 00:00:00
NLMK SHARON COATING, LLC
CUDDY, PA—2026-07-08 00:00:00
SUPERIOR POWDER COATING INC
More inspections in WI
GREEN BAY, WI—2026-07-17 00:00:00
PTS CONTRACTORS, INC.
WAUSAU, WI—2026-07-16 00:00:00
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15 00:00:00
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15 00:00:00
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15 00:00:00
TERONOMY BUILDERS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342933413.