Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: PREMIER POWDERCOATING, INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of PREMIER POWDERCOATING, INC. in 15812 BRIDGE ST, ETTRICK, WI 54627 (NAICS 332812). OSHA activity number 342933413.

Watch Premier Powdercoating, INC. — free Get an email when a new federal OSHA severe-injury report for Premier Powdercoating, INC. is published. One employer, no account, unsubscribe in one click.
Site address
15812 BRIDGE ST
City
ETTRICK
State
WI
ZIP
54627
Mailing
PO BOX 95, ETTRICK, WI 54627
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
2
Ownership type
A

2 citations on file for this inspection.

1910.134 E01

Repeat Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5543.00 · Current $5543.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    (a) Abrasive Blasting Area; The employer does not provided medical evaluations for employee(s) who are required to wear half-mask elastomeric and air supplied hood respirators while abrasive blasting.      Premier Powdercoating, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(e)(1), which was contained in OSHA inspection number 1021062, citation number 1, item number 1/C and was affirmed as a final order on July 21, 2015, with respect to a workplace located at 15812 Bridge St. in Ettrick, WI.
Recent events (3)
  • — A (R) $5543
  • — I (R) $3880
  • — Z (R) $5543

1910.94 A04 III

Repeat 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1109.00 · Current $1109.00
29 CFR 1910.94(a)(4)(iii): Air exhausted from blast-cleaning equipment was not discharged through dust collecting equipment:    (a) Abrasive Blasting Area; The employer does not require air exhausted from the blast-cleaning equipment to be discharged through dust collecting equipment.     Premier Powdercoating, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.94(a)(4)(iii), which was contained in OSHA inspection number 1021062, citation number 2, item number 1 and was affirmed as a final order on July 21, 2015, with respect to a workplace located at 15812 Bridge St. in Ettrick, WI.
Recent events (3)
  • — A (R) $1109
  • — I (R) $775
  • — Z (R) $1109

View PREMIER POWDERCOATING, INC.'s full OSHA safety record →