OSHA Inspection: PRO-SPEC CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRO-SPEC CORPORATION in QUAKERTOWN WASTE SEWAGE TREATMENT PLANT 777 EAST BROAD STREET, QUAKERTOWN, PA 18951 (NAICS 238320). OSHA activity number 341744043.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pro-Spec Corporation — free Get an email when a new federal OSHA severe-injury report for Pro-Spec Corporation is published. One employer, no account, unsubscribe in one click.
Site address
QUAKERTOWN WASTE SEWAGE TREATMENT PLANT 777 EAST BROAD STREET
City
QUAKERTOWN
State
PA
ZIP
18951
Mailing
1819 CEDAR AVENUE, VINELAND, NJ 08360
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
4
Ownership type
A

9 citations on file for this inspection.

1910.134 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 9, 2017
Abate by
Jan 23, 2017
Penalty
Initial $6,360 · Current $6,360
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a) Pro-Spec Corporation DBA: Pro-Spec Painting Inc. - On or about August 17, 2016, the employer did not provide employees a medical evaluation before the employee was fit tested or required to wear a respirator to conduct abrasive blasting and painting operations.
Recent events (3)
  • — J (S) $6360
  • — C (S) $6360
  • — Z (S) $6360

1910.134 F01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 9, 2017
Abate by
Jan 23, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting face piece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  a) Pro-Spec Corporation DBA: Pro-Spec Painting Inc. - On or about August 17, 2016, the employer did not ensure that each employee required to use a tight-fitting face piece had passed the appropriate fit testing prior to wearing the face piece to conduct abrasive blasting and painting operations.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 I05 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 9, 2017
Abate by
Jan 23, 2017
Penalty
Initial $6,360 · Current $6,360
29 CFR 1910.134(i)(5)(iv): The employer did not ensure that the person authorized to perform the necessary sorbent bed and filter changes filled out a tag indicating by the signature and date that maintenance changes were performed:  a) Pro-Spec Corporation DBA: Pro-Spec Painting Inc. - On or about August 31, 2016, a sorbent bed and filter changes were not documented with a legible tag indicating the signature and date that maintenance changes were performed.
Recent events (3)
  • — J (S) $6360
  • — C (S) $6360
  • — Z (S) $6360

1926.451 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 9, 2017
Penalty
Initial $3,180 · Current $3,180
29 CFR 1926.451(e)(1): Where scaffold platforms were more than 2 feet above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers, stairway-type ladders, ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used for access:  a) Pro-Spec Corporation DBA: Pro-Spec Painting Inc. - On or about August 31, 2016, employees were accessing two system scaffold platforms by climbing up on horizontal members.
Recent events (3)
  • — J (S) $3180
  • — C (S) $3180
  • — Z (S) $3180

1926.1053 B05 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 9, 2017
Penalty
Initial $4,240 · Current $4,240
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder.   a) Pro-Spec Corporation DBA: Pro-Spec Painting Inc. - On or about August 31, 2016, a portable aluminum ladder was being used at an angle such that the horizontal distance from the top support to the foot of the ladder was in excess of one-quarter of the working length of the ladder.
Recent events (3)
  • — J (S) $4240
  • — C (S) $4240
  • — Z (S) $4240

1926.1053 B16

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 9, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired.  a) Pro-Spec Corporation DBA: Pro-Spec Painting Inc. - On or about August 31, 2016, a portable aluminum ladder was being used without shoes, cleats, or other anti-slip devices at the base to prevent inadvertent movement.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.405 A02 II I

Other-than-serious 1 instance 1 exposed
Issued
Jan 9, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(I): Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points:  a) Pro-Spec Corporation DBA: Pro-Spec Painting Inc.- On or about August 31, 2016, protection was not provided to avoid damage to a flexible extension cord that passed through a doorway to the blower room.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

1926.405 G02 IV

Other-than-serious 1 instance 1 exposed
Issued
Jan 9, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  a) Pro-Spec Corporation DBA: Pro-Spec Painting Inc.- On or about August 31, 2016, the female connection of a flexible extension cord was not connected so that strain relief was provided to prevent pull from being directly transmitted to joints or terminal screws.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

1926.1207 D

Other-than-serious 1 instance 5 exposed
Issued
Jan 9, 2017
Abate by
Jan 23, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1207(d): The employer did not maintain training records to show that the training required by paragraphs (a) through (c) of this standard has been accomplished by identifying each employee's name, the name of the trainers, and the dates of training.  a) Pro-Spec Corporation DBA: Pro-Spec Painting Inc. - On or about August 17, 2016, the employer did not maintain training records to identify that employees performing construction work involving confined spaces had received training related to the hazards in the permit space and the methods used to isolate, control or in other ways protect employees from these hazards.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

View Pro-Spec Corporation's full OSHA safety record →