Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: IRONROCK CAPITAL, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of IRONROCK CAPITAL, INC. in 1201 MILLERTON STREET SE, CANTON, OH 44707 (NAICS 327120). OSHA activity number 341753093.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ironrock Capital, INC. — free Get an email when a new federal OSHA severe-injury report for Ironrock Capital, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1201 MILLERTON STREET SE
City
CANTON
State
OH
ZIP
44707
Mailing
1201 MILLERTON STREET SE, CANTON, OH 44707
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327120
Employees
85
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 28, 2016
Abate by
Oct 18, 2016
Penalty
Initial $8,730 · Current $6,550 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    On or about 8/29/2016, the employer failed to ensure that the lockout/tagout procedures that were developed for the Robot Packaging Line 3 North Grouping, prevented the release of hazardous energy of the robot stacker arm.
Recent events (2)
  • — I (S) $6550
  • — Z (S) $8730

1910.147 D

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 28, 2016
Abate by
Oct 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  On or about 8/29/2016, the employer failed to ensure that the following procedures were followed when performing maintenance on the Robot 1 Packaging Line 3 North Grouping:  1910.147(d)(1) Preparation for shutdown. Before an authorized or affected employee turns off a machine or equipment, the authorized employee shall have knowledge of the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy.  1910.147(d)(2) Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage.  1910.147(d)(3) Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).  1910.147(d)(4) Lockout or tagout device application.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0