Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MIAMI TECH, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MIAMI TECH, INC. in 6650 NW 37TH AVE., MIAMI, FL 33147 (NAICS 332322). OSHA activity number 341753440.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Miami Tech, INC. — free Get an email when a new federal OSHA severe-injury report for Miami Tech, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MIAMI TECH, INC.
Site address
6650 NW 37TH AVE.
City
MIAMI
State
FL
ZIP
33147
Mailing
3611 NW 74 ST., MIAMI, FL 33147
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
83
Ownership type
A

3 citations on file for this inspection.

1910.217 C04

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 27, 2017
Abate by
Feb 2, 2017
Penalty
Initial $8,873 · Current $8,873
29 CFR 1910.217(c)(4): Hand feeding tools. Hand feeding tools are intended for placing and removing materials in and from the press. Hand feeding tools are not a point of operation guard or protection device and shall not be used in lieu of the "guards" or devices required in this section:   a.  On or about September 2nd, 2016, at the above addressed jobsite, in the manufacturing area, an employee was exposed to an amputation hazard, while working with a press, and placing and removing materials without hand tools.
Recent events (1)
  • — Z (S) $8873

1910.217 F02

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 27, 2017
Abate by
Feb 2, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.217(f)(2): Supervision to ensure that correct operating procedures were being followed on mechanical power press(es) was inadequate:  a.  On or about September 2nd, 2016, at the above addressed jobsite, in the manufacturing area, an employee did not receive the proper supervision while operating a power press.  The employee was exposed to an amputation hazard when placing and removing materials in the point of operation without  using hand tools.
Recent events (1)
  • — Z (S) $0

1910.217 E01 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 27, 2017
Abate by
Feb 8, 2017
Penalty
Initial $8,873 · Current $8,873
29 CFR 1910.217(e)(1)(i)(A): Periodic and regular inspections of each power press were not conducted to ensure that all of its parts, auxiliary equipment, and safeguards, including clutch/brake mechanism, antirepeat feature, and single-stroke mechanism, are in safe operating condition and adjustment:  a.  On or about September 2nd, 2016, at the above addressed jobsite, in the manufacturing area, an employee was exposed to an amputation hazard, while working with a press that had not been properly inspected.
Recent events (1)
  • — Z (S) $8873

View Miami Tech, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341753440.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.