TAMUNING, GU —
OSHA Inspection: COCO COMMERCIAL PROPERTY
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of COCO COMMERCIAL PROPERTY in OLD HAWAIIAN BANK BUILDING MARINE CORPS DRIVE, TAMUNING, GU 96913 (NAICS 236220). OSHA activity number 341757326.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COCO COMMERCIAL PROPERTY
- Site address
- OLD HAWAIIAN BANK BUILDING MARINE CORPS DRIVE
- City
- TAMUNING
- State
- GU
- ZIP
- 96913
- Mailing
- 456 S. MARINE CORPS DRIVE STE 102, TAMUNING, GU 96913
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 9
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.403 B02
- Issued
- Nov 4, 2016
- Abate by
- Nov 21, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification. a) At the Old Hawaiian Bank Building repair/renovation project, two household fans were used in the renovation/repair project for air circulation.
Recent events (1)
- — Z (O) $0
1926.405 G02 IV
- Issued
- Nov 4, 2016
- Abate by
- Nov 21, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws. a) At the Old Hawaiian Bank Building repair/renovation project, the orange extension cord used for hand tools did not have strain relief, insulation pulled from the plug.