NORTH VENICE, FL —
OSHA Inspection: PGT INDUSTRIES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PGT INDUSTRIES, INC. in 1070 TECHNOLOGY DR., NORTH VENICE, FL 34275 (NAICS 327215). OSHA activity number 341759751.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PGT INDUSTRIES, INC.
- Site address
- 1070 TECHNOLOGY DR.
- City
- NORTH VENICE
- State
- FL
- ZIP
- 34275
- Mailing
- 1070 TECHNOLOGY DR., NORTH VENICE, FL 34275
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327215
- Employees
- 1900
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II
- Issued
- Feb 16, 2017
- Abate by
- Mar 1, 2017
- Penalty
- Initial $9,959 · Current $9,959
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): (a) In the Manufacturing Department, for machinery, such as but not limited to, SGD 470-570 PVC die machine, where procedures for lock out/tag out were not developed when authorized employees were changing dies, on or about September 08, 2016.
Recent events (1)
- — Z (S) $9959
1910.147 C06 I
- Issued
- Feb 16, 2017
- Abate by
- Mar 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) In the Manufacturing Department, for machinery, such as but not limited to, SGD 470-570 PVC die machine, on or about September 08, 2016.
Recent events (1)
- — Z (O) $0
More inspections at PGT Industries, INC.
View PGT Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327215)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341759751.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.