Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HAINES EQUIPMENT INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HAINES EQUIPMENT INC. in 20 CARRINGTON STREET, AVOCA, NY 14809 (NAICS 333111). OSHA activity number 341760130.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Haines Equipment INC. — free Get an email when a new federal OSHA severe-injury report for Haines Equipment INC. is published. One employer, no account, unsubscribe in one click.
Site address
20 CARRINGTON STREET
City
AVOCA
State
NY
ZIP
14809
Mailing
20 CARRINGTON STREET, AVOCA, NY 14809
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333111
Employees
13
Ownership type
A

12 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 9 instances 8 exposed
Issued
Oct 19, 2016
Abate by
Nov 23, 2016
Penalty
Initial $4,276 · Current $2,566 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks    a)  Assembly Building, on or about 9/8/16:  Wilton horizontal bandsaw was not provided with a guard to cover 7-1/2 inches of unused blade.    b)  Assembly Building, on or about 9/8/16:  Walker Turner drill press was not equipped with a chuck and tool guard.    c)  Assembly Building, on or about 9/8/16:   Central Machine drill press was not equipped with a chuck and tool guard.    d)  Assembly Building, on or about 9/8/16:  MS32 drill press was not equipped with a chuck and tool guard.     e)  Assembly Building, on or about 9/8/16:  Milwaukee magnetic drill was not equipped with a chuck and tool guard.    f)  Machine Room, on or about 9/8/16:  Southbend MR06 Lathe was not equipped with a chuck and tool guard.    g)  Machine Room, on or about 9/8/16:  Bridgeport endmill was not equipped with a chuck and tool guard.    h)  Machine Room, on or about 9/8/16:  Hendey Lathe was not equipped with a chuck and tool guard.    i)  Back Shop, on or about 9/8/16:  Dayton drill press was not equipped with a chuck and tool guard.
Recent events (3)
  • — F (S) $2565.6
  • — C (S) $4276
  • — Z (S) $4276

1910.212 A05

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 19, 2016
Abate by
Oct 31, 2016
Penalty
Initial $2,850 · Current $1,710 Reduced
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level:    a)  Back Shop, on or about 9/8/16:  Blower fan used for cooling purposes was not equipped with a guard to prevent contact with the rotating fan blades.
Recent events (3)
  • — F (S) $1710
  • — C (S) $2850
  • — Z (S) $2850

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 19, 2016
Abate by
Oct 31, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  a)  Back Shop, on or about 9/8/16:  Blower fan setting on top of a work bench was not equipped with a guard to cover the in-running nip points of the belt and pulley.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.219 E01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 19, 2016
Abate by
Oct 31, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:    a)  Back Shop, on or about 9/8/16:  Blower fan setting on top of a work bench was not equipped with a guard to cover the in-running nip points of the belt and pulley.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.215 B09

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Oct 19, 2016
Abate by
Oct 31, 2016
Penalty
Initial $2,850 · Current $0 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a)  Machine Room, on or about 9/8/16:  MR17 Bench Grinder had the tongue guards adjusted 3/4-inch from the left side wheel and 5/8-inch from the right side wheel.
Recent events (3)
  • — F (S) $0
  • — C (S) $2850
  • — Z (S) $2850

1910.242 B

Serious Gravity 5 2 instances 1 exposed
Issued
Oct 19, 2016
Abate by
Oct 31, 2016
Penalty
Initial $2,850 · Current $1,710 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    a)  Machine Shop, on or about 9/8/16:  (2) Two compressed air lines used from cleaning purposes were delivering air pressures greater than 100 p.s.i.
Recent events (3)
  • — F (S) $1710
  • — C (S) $2850
  • — Z (S) $2850

1910.254 D09 III

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 19, 2016
Abate by
Oct 31, 2016
Penalty
Initial $2,850 · Current $1,710 Reduced
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replace:    a)  Assembly Building, on or about 9/8/16:  L-TEC MIG Welder was operated with cable insulation damaged and conductors exposed.
Recent events (3)
  • — F (S) $1710
  • — C (S) $2850
  • — Z (S) $2850

1910.303 B02

Serious Gravity 5 2 instances 3 exposed
Issued
Oct 19, 2016
Abate by
Oct 31, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a)  Assembly Building, Belt/Donut Cutting Area, on or about 9/8/16:  Cooling fan power cord had two different types of flexible cord spliced and held together with electrical tape.    b)  Back Shop, on or about 9/8/16:  Cooling fan flexible power cord had an electrical switch box spliced into the cord.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.305 G02 II

Serious Gravity 5 2 instances 3 exposed
Issued
Oct 19, 2016
Abate by
Oct 31, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  a)  Back Shop, on or about 9/8/16:  The power cord to a portable cooling fan had been spliced and connected together with wire nuts.    b)  Assembly Building, Belt/Donut Cutting Area, on or about 9/8/16:  The power cord to a portable cooling fan had been spliced with a different cord and connected with electrical tape.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 19, 2016
Abate by
Oct 31, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  a)  Assembly Building, Welding Area, on or about 9/8/16:  L-Tech MIG Welder conductors entering into the plug assembly were pulled from the plug and thereby exposed.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.37 A03

Other-than-serious 1 instance 9 exposed
Issued
Oct 19, 2016
Abate by
Oct 31, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:   a)  Back Shop, on or about 9/8/16:  Exit door in the rear of the shop was locked and did not allow free access to the outside.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.37 B02

Other-than-serious 1 instance 9 exposed
Issued
Oct 19, 2016
Abate by
Oct 31, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  a)  Back Shop, on or about 9/8/16:  Exit door was not identified with a sign reading "Exit".
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Haines Equipment INC.'s full OSHA safety record →