Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE DENOMINATOR COMPANY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of THE DENOMINATOR COMPANY, INC. in 744 MAIN STREET SOUTH, WOODBURY, CT 06798 (NAICS 334514). OSHA activity number 341766418.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Denominator Company, INC. — free Get an email when a new federal OSHA severe-injury report for The Denominator Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
744 MAIN STREET SOUTH
City
WOODBURY
State
CT
ZIP
06798
Mailing
P.O. BOX 5004, WOODBURY, CT 06798
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334514
Employees
6
Ownership type
A

12 citations on file for this inspection.

1910.24 H

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 31, 2016
Abate by
Dec 19, 2016
Penalty
Initial $1,604 · Current $962 Reduced
29 CFR 1910.24(h): Stair railings and handrails were not installed in accordance with 29 CFR 1910.23:  Basement Stairs:  On, or about, September 12, 2016, the wooden stairs leading from the main level to the Basement Press Room did not meet construction requirements in that:  A.  The top rail was measured to be 27 inches above the nose of the tread. B.  The top rail was not the equivalent of 2 x 4 inch stock. C.  A midrail was not provided.    Ref. 29 CFR 1910.23(e)(2) and 29 CFR 1910.23(e)(3)(i)
Recent events (2)
  • — I (S) $962.4
  • — Z (S) $1604

1910.213 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 31, 2016
Abate by
Dec 19, 2016
Penalty
Initial $2,672 · Current $1,603 Reduced
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material being cut:    Basement Press Room:  On, or about, September 12, 2016, the DeWalt Model 7790 radial arm saw was not provided with a lower blade guard.
Recent events (2)
  • — I (S) $1603.2
  • — Z (S) $2672

1910.217 B03 I

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 31, 2016
Abate by
Dec 19, 2016
Penalty
Initial $1,604 · Current $962 Reduced
29 CFR 1910.217(b)(3)(i): Mechanical power press(es) using full revolution clutches did not incorporate a single-stroke mechanism:  Basement Press Room:  On, or about, September 12, 2016, the Excelsior bench mounted full revolution mechanical power press was not provided with a single stroke mechanism.
Recent events (2)
  • — I (S) $962.4
  • — Z (S) $1604

1910.217 B04 I

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 31, 2016
Abate by
Dec 19, 2016
Penalty
Initial $1,604 · Current $962 Reduced
29 CFR 1910.217(b)(4)(i): Pedal mechanism(s) on mechanical power press(es) full revolution clutches were not protected to prevent unintended operation from falling or moving objects or by accidental stepping onto the pedals:   Basement Press Room:  On, or about, August 22, 2016, a guard was not provided on the foot pedal used to operate the Perkins Model 450-B full revolution mechanical power press.
Recent events (2)
  • — I (S) $962.4
  • — Z (S) $1604

1910.217 B08 II

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 31, 2016
Abate by
Dec 19, 2016
Penalty
Initial $1,604 · Current $962 Reduced
29 CFR 1910.217(b)(8)(ii): Motor start button(s) of mechanical power press(es) were not protected against accidental operation:  Basement Press Room:  On, or about, September 12, 2016, a single pole snap switch was provided to turn the power on to the Excelsior bench mounted mechanical power press.
Recent events (2)
  • — I (S) $962.4
  • — Z (S) $1604

1910.217 B08 III

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 31, 2016
Abate by
Dec 19, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.217(b)(8)(iii): Mechanical power press control(s) did not incorporate a type of drive motor starter that would disconnect the drive motor from the power source in event of control voltage or power source failure and require operation of the motor start button to restart the motor when voltage conditions were restored to normal:  Basement Press Room:  On, or about, September 12, 2016, the Excelsior bench mounted mechanical power press was not provided with a drop-out starter that would prevent the press was re-energizing in the event of a power loss.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 C01 I

Serious Gravity 10 3 instances 1 exposed
Issued
Oct 31, 2016
Abate by
Dec 19, 2016
Penalty
Initial $3,741 · Current $2,245 Reduced
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es):  Basement Press Room:  On, or about, August 22, 2016, the following mechanical power presses were not provided with adequate safeguarding for the point of operation:  A.  Perkins Model 450-B:  The Woodbury pullback device was missing several components and was not usable.  An employee suffered serious injuries when his hand was caught in the die while stamping parts.  B.  Perkins Model 351-B:  The Woodbury pullback device was missing several components and was not usable.  C.  Excelsior bench press:  The Woodbury pullback device was not used when the press was used to stamp end plates.  Also, no one at the company was trained regarding the proper set-up of the device and the device was not routinely inspected.
Recent events (2)
  • — I (S) $2244.6
  • — Z (S) $3741

1910.217 E01 I A

Serious Gravity 5 3 instances 2 exposed
Issued
Oct 31, 2016
Abate by
Dec 19, 2016
Penalty
Initial $2,672 · Current $1,603 Reduced
29 CFR 1910.217(e)(1)(i)(A): Periodic and regular inspections of each power press were not conducted to ensure that all of its parts, auxiliary equipment, and safeguards, including clutch/brake mechanism, antirepeat feature, and single-stroke mechanism, are in safe operating condition and adjustment:  Basement Press Room:  On, or about, September 12, 2016, the company had not developed and implemented an inspection program for mechanical power presses.
Recent events (2)
  • — I (S) $1603.2
  • — Z (S) $2672

1910.217 E01 II A

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 31, 2016
Abate by
Dec 19, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.217(e)(1)(ii)(A): Inspections and tests of each press on a weekly basis were not being completed to determine the condition of the clutch/ brake mechanism, anti repeat feature and single stroke mechanism:  Basement Press Room:  On, or about, September 12, 2016, the company did not test mechanical power presses on a weekly basis.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.39 A02

Other-than-serious 1 instance 1 exposed
Issued
Oct 31, 2016
Abate by
Dec 19, 2016
Penalty
Initial $1,500 · Current $900 Reduced
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours:  Company:  On, or about, September 12, 2016, the employer had not reported an injury to an employee that occurred on August 22, 2016 that resulted in the partial amputation of the employee's finger.
Recent events (2)
  • — I (O) $900
  • — Z (O) $1500

1910.36 G02

Other-than-serious 1 instance 1 exposed
Issued
Oct 31, 2016
Abate by
Dec 19, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points:  Basement Press Room:  On, or about, September 12, 2016, the pay-off unit provided for the Perkins Model 450-B mechanical power press was partially blocking the access to the exit door.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.217 G

Other-than-serious 1 instance 1 exposed
Issued
Oct 31, 2016
Abate by
Dec 19, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.217(g): The employer did not report within 30 days of the occurrence, to either the Director of the Office of Standards Development OSHA, U.S. Department of Labor, Washington, D.C. 20210:  Company:  On, or about, October 21, 2016, the employer had not reported an injury that an employee suffered while working on a Perkins full revolution mechanical power press on August 22, 2016.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0