OSHA Inspection: GENERAL SERVICES ADMINISTRATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GENERAL SERVICES ADMINISTRATION in 500 STATE AVENUE, KANSAS CITY, KS 66101 (NAICS 921190). OSHA activity number 341792430.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Services Administration — free Get an email when a new federal OSHA severe-injury report for General Services Administration is published. One employer, no account, unsubscribe in one click.
Site address
500 STATE AVENUE
City
KANSAS CITY
State
KS
ZIP
66101
Mailing
GSA REGION 6 2300 MAIN STREET, KANSAS CITY, MO 64108
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
921190
Employees
20
Ownership type
D

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 10 instances 4 exposed
Issued
Feb 3, 2017
Abate by
Jun 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Employees were exposed to struck by and caught in hazards.  Guards were not provided to protect employees from moving/rotating parts of equipment and ingoing nip points.  Guards were not provided in the following locations:              In the 9th floor elevator equipment room.               - Elevator lift equipment #1, rotating parts of the brake assembly.         - Elevator lift equipment #2, rotating parts of the brake assembly.         - Elevator lift equipment #3, rotating parts of the brake assembly.         - Elevator lift equipment #4, rotating parts of the brake assembly.         - Elevator lift equipment #5, rotating parts of the lift pulley assembly.         - elevator lift equipment #5, in going nip point created by the lift pulley assembly and wire rope.      In the 5th floor elevator equipment rooms.          - Elevator lift equipment #6, rotating parts of the lift pulley assembly.         - Elevator lift equipment #6, in going nip point created by the lift pulley assembly and wire rope.         - Elevator lift equipment #7, rotating parts of the lift pulley assembly.         - Elevator lift equipment #7, in going nip point created by the lift pulley assembly and wire rope.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C02 I

Serious Gravity 5 4 instances 4 exposed
Issued
Feb 3, 2017
Abate by
Jun 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  Employees were exposed to amputation hazards.  Guards were not provided for the rotating shafts between the motor and associated lift equipment in the following locations:          In the 9th floor elevator equipment room.               - Elevator lift equipment #5.         - Elevator lift equipment #8.      In the 5th floor elevator equipment rooms.          - Elevator lift equipment #6.         - Elevator lift equipment #7.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 4 instances 4 exposed
Issued
Feb 3, 2017
Abate by
Jun 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  Employees were exposed to electrical shock hazards.  Guards were not provided to prevent contact with the 480 volt motor armatures on elevator lift equipment in the following locations:       In the 9th floor elevator equipment room.               - Elevator lift equipment #1.         - Elevator lift equipment #2.         - Elevator lift equipment #3.         - Elevator lift equipment #4.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View General Services Administration's full OSHA safety record →