Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PICOMA INDUSTRIES

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PICOMA INDUSTRIES in 9208 JEFFREY DRIVE, CAMBRIDGE, OH 43725 (NAICS 331210). OSHA activity number 341793123.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Picoma Industries — free Get an email when a new federal OSHA severe-injury report for Picoma Industries is published. One employer, no account, unsubscribe in one click.
Establishment
PICOMA INDUSTRIES
Site address
9208 JEFFREY DRIVE
City
CAMBRIDGE
State
OH
ZIP
43725
Mailing
9208 JEFFREY DRIVE, CAMBRIDGE, OH 43725
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
98
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 1 instance 6 exposed
Issued
Oct 12, 2016
Abate by
Oct 24, 2016
Penalty
Initial $11,224 · Current $7,857 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.    a. On or about September 23, 2016 and at times prior, employees were operating a hydraulic rotary pipe bender manufactured by Pines Engineering, Picoma Bender 6, Serial 11630-11015, to form metal conduit pipe. Employees would enter into the hazardous area of the machine to position the pipe, hold the pipe by hand while the bender completed the cycle, and remove the pipe from the machine. An unguarded point of operation and pinch point area between the rotating clamp arm and the machine exposed employees to a crushed by hazard.
Recent events (2)
  • — I (S) $7857
  • — Z (S) $11224

1910.147 C04 II

Deleted Other-than-serious 1 instance 6 exposed
Issued
Oct 12, 2016
Abate by
Oct 24, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:  a. On or about September 23, 2016 and at times prior, the employer's energy control procedure for the hydraulic rotary pipe bender manufactured by Pines Engineering, Picoma Bender 6, Serial 11630-11015, did not contain adequate information to include, but not limited to, the following:    (1) A specific statement of the intended use of the procedure pursuant to 1910.147(c)(4)(ii)[A]. The procedure did not include a statement to inform employees of the intended use of the procedure.    (2) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy pursuant to 1910.147(c)(4)(ii)[B]. The procedure did not include methods for shutting down, isolating, and controlling the hydraulic hazardous energy source.    (3) Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures 1910.147(c)(4)(ii)[D]. The procedure lacked specific steps to verify that isolation and deenergization of the hydraulic energy source was accomplished.
Recent events (3)
  • — D (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.147 C07 I A

Other-than-serious 1 instance 6 exposed
Issued
Oct 12, 2016
Abate by
Oct 9, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:      a. On or about September 23, 2016,  the employer failed to fully document its training of an authorized assistant to a laborer with regard to the use of a group lock-out/tag-out device.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Picoma Industries's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341793123.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.