OSHA Inspection: OLIVER SIDING LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OLIVER SIDING LLC in 1719 LASALLE ST., BELLEVILLE, IL 62221 (NAICS 238160). OSHA activity number 341798536.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Oliver Siding LLC — free Get an email when a new federal OSHA severe-injury report for Oliver Siding LLC is published. One employer, no account, unsubscribe in one click.
Establishment
OLIVER SIDING LLC
Site address
1719 LASALLE ST.
City
BELLEVILLE
State
IL
ZIP
62221
Mailing
9 MUSTANG TRL CT., SAINT PETERS, MO 63376
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

9 citations on file for this inspection.

1926.20 B01

Serious Gravity 5 5 instances 5 exposed
Issued
Sep 27, 2016
Abate by
Jan 18, 2017
Penalty
Initial $2,672 · Current $1,086 Reduced
29 CFR 1926.20(b)(1):  The employer did not initiate and maintain accident prevention programs as necessary to comply with this part:      The employer did not initiate and maintain an accident prevention program to establish criteria for protecting employees from fall from heights, struck by, and electrocution hazards.
Recent events (3)
  • — F (S) $1086
  • — C (S) $2672
  • — Z (S) $2672

1926.20 B02

Serious Gravity 5 5 instances 5 exposed
Issued
Sep 27, 2016
Abate by
Jan 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.20(b)(2):  The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):      The employer did not maintain jobsite inspections that were performed by a person competent to ensure employees were not exposed to fall from height hazards, struck-by hazards, and electrocution hazards during roofing operations.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.152 D04

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 27, 2016
Abate by
Sep 28, 2016
Penalty
Initial $3,741 · Current $0 Reduced
29 CFR 1926.152(d)(4): At least one portable fire extinguisher having a rating of not less than 20B:C units was not provided on all vehicles used for transporting and/or dispensing flammable or combustible liquids:    The employer did not ensure that a portable fire extinguisher was available to employees who were carrying a 5 gallon gasoline can in the vehicle. The gasoline was being used to fill the air compressor.
Recent events (3)
  • — F (S) $0
  • — C (S) $3741
  • — Z (S) $3741

1926.100 A

Serious Gravity 5 2 instances 1 exposed
Issued
Sep 27, 2016
Abate by
Sep 28, 2016
Penalty
Initial $2,138 · Current $870 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:      Head protective equipment was not used when workers were exposed to struck-by hazards when workers on the ground were working below unsecured tools and material on the roof.
Recent events (3)
  • — F (S) $870
  • — C (S) $2138
  • — Z (S) $2138

1926.102 A01

Serious Gravity 5 2 instances 4 exposed
Issued
Sep 27, 2016
Abate by
Sep 28, 2016
Penalty
Initial $2,138 · Current $0 Reduced
29 CFR 1926.102(a)(1):  Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:      Eye protective equipment was not used when employees were exposed to eye injury while using pneumatic nail guns.
Recent events (3)
  • — F (S) $0
  • — C (S) $2138
  • — Z (S) $2138

1926.416 A01

Serious Gravity 10 2 instances 4 exposed
Issued
Sep 27, 2016
Abate by
Sep 28, 2016
Penalty
Initial $3,741 · Current $1,522 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    The employer did not ensure that circuits were de-energized or insulated when employees working to remove asphalt roofing shingles in close proximity to a 120/208v triplex service drop.
Recent events (3)
  • — F (S) $1522
  • — C (S) $3741
  • — Z (S) $3741

1926.416 A03

Serious Gravity 10 3 instances 4 exposed
Issued
Sep 27, 2016
Abate by
Sep 28, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into physical or electrical contact with the electric power circuit.  The employer did not ensure that the electrical lines from the service drop were located so that employees working to install asphalt shingles on the roof of a commercial building would not come in contact with electrical power circuit from a 120/208v triplex service drop.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 2 instances 4 exposed
Issued
Sep 27, 2016
Abate by
Sep 28, 2016
Penalty
Initial $3,741 · Current $1,522 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:      The employer did not ensure fall protection was implemented during residential construction operations when:    A:  Workers were exposed to the hazard of falling approximately eleven (11) feet off the roof eve when they were installing roof shingles on a single family structure.      B.  Workers were exposed to the hazard of falling approximately seven (7) feet off the roof eve when they were installing roof shingles on a garage structure.
Recent events (3)
  • — F (S) $1522
  • — C (S) $3741
  • — Z (S) $3741

1926.503 A01

Serious Gravity 5 2 instances 5 exposed
Issued
Sep 27, 2016
Abate by
Oct 19, 2016
Penalty
Initial $2,672 · Current $0 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards:    The employer did not provide fall protection training to enable employees to recognize and control the fall hazards at their worksite while performing residential construction.  Employees were exposed to the hazard of falling up to  approximately eleven (11) feet.
Recent events (3)
  • — F (S) $0
  • — C (S) $2672
  • — Z (S) $2672

View Oliver Siding LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341798536.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.