ALLIANCE, OH —
OSHA Inspection: R.W. SIDLEY, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of R.W. SIDLEY, INC. in 2000 BEESON ST, ALLIANCE, OH 44601 (NAICS 327320). OSHA activity number 341801256.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R.W. SIDLEY, INC.
- Site address
- 2000 BEESON ST
- City
- ALLIANCE
- State
- OH
- ZIP
- 44601
- Mailing
- 436 CASEMENT AVE., PAINESVILLE, OH 44077
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327320
- Employees
- 8
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.23 C01
- Issued
- Nov 23, 2016
- Abate by
- Dec 14, 2016
- Penalty
- Initial $8,907 · Current $4,454 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: On or about October 11, 2016, employees were exposed to a fall of 7 feet 5 inches when accessing an overhead storage area in the garage to retrieve miscellaneous parts including, but not limited to PVC pipes and joints. The open side was missing a top rail, mid rail, and toe board in an area where employees pass directly below.
Recent events (2)
- — I (S) $4453.5
- — Z (S) $8907
1910.132 D02
- Issued
- Nov 23, 2016
- Abate by
- Dec 14, 2016
- Penalty
- Initial $5,347 · Current $2,674 Reduced
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: On or about October 11, 2016 employees working in the yard were exposed to hazards associated with concrete additives including, but not limited to, Portland Cement. A hazard assessment had not been conducted and documented.
Recent events (2)
- — I (S) $2673.5
- — Z (S) $5347
1910.147 C06 I
- Issued
- Nov 23, 2016
- Abate by
- Dec 14, 2016
- Penalty
- Initial $8,907 · Current $4,454 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about October 11, 2016, the employer had not conducted periodic inspections of energy control procedures where employees service equipment including, but not limited to, dust collectors and motors.
Recent events (2)
- — I (S) $4453.5
- — Z (S) $8907
1910.147 D
- Issued
- Nov 23, 2016
- Abate by
- Dec 14, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedure) was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6): On or about October 11, 2016, employees were exposed to machine hazards associated with moving parts and electrical hazards during servicing and cleaning of the dust collectors, motors, and bag houses. The employer failed to implement energy control application steps as there was not proper preparation for shutdown [per the 1910.147(d)(1) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards. prepare for shutdown [(d)(1)] - ensure authorized employee has knowledge of the type, magnitude, the hazards, and the method or means to control the energy; shutdown the machine or equipment [(d)(2)]; machine isolation [(d)(3)] Physically locate and operate all energy isolating devices that are needed to control the energy to the machine or equipment In such a manner as to isolate the machine or equipment from the energy sources(s); LOTO device application [(d)(4)] Affix a lockout or tagout device to each energy isolating device; dissipation of residual energy [(d)(5)(i)] relieve, disconnect, restrain, and otherwise render safe all potentially hazardous stored or residual energy; verification of isolation [(d)(6)] Verify that isolation and deenergization of the machine or equipment has been accomplished.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at R.W. Sidley, INC.
View R.W. Sidley, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327320)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341801256.