Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WHITAKER CONSTRUCTION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WHITAKER CONSTRUCTION in 232 REDONDO DE FRANCISCO, TAMUNING, GU 96913 (NAICS 236115). OSHA activity number 341817039.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Whitaker Construction — free Get an email when a new federal OSHA severe-injury report for Whitaker Construction is published. One employer, no account, unsubscribe in one click.
Site address
232 REDONDO DE FRANCISCO
City
TAMUNING
State
GU
ZIP
96913
Mailing
P.O. BOX 11092, YIGO, GU 96929
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
8
Ownership type
A

5 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 18, 2016
Penalty
Initial $1,817 · Current $1,272 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.  (a) On October 6, 2016, there was no assured equipment grounding conductor program or ground-fault circuit-interrupter protection when employees used a 110 VAC Milwaukee circular saw, powered through an extension cord.
Recent events (2)
  • — I (S) $1271.9
  • — Z (S) $1817

1926.404 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  (a) On October 6, 2016, on the roof top, the path to ground on a 110 VAC non ground fault circuit interrupter receptacle used to supply power to a 50 foot green and red extension cord was not permanent and continuous.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 18, 2016
Penalty
Initial $1,817 · Current $1,272 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   (a) On October 6, 2016, at the roof level, employees engaged in residential form were not protected by guardrail systems, safety net systems, or personal fall arrest systems.  Employees were exposed to fall hazards.
Recent events (2)
  • — I (S) $1271.9
  • — Z (S) $1817

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 18, 2016
Penalty
Initial $1,817 · Current $1,272 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   (a)  On October 6, 2016, a 6 foot Werner aluminum stepladder used to gain access to the work area did not extend at least 3 feet above the landing, the ladder was not secured and there was no grab rail at the top of the landing.
Recent events (2)
  • — I (S) $1271.9
  • — Z (S) $1817

1926.405 G02 IV

Other-than-serious 1 instance 2 exposed
Issued
Oct 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  (a) On October 6, 2016, at the project site, the outer insulation on the 50 foot red and green extension cord that supplied power to a Milwaukee circular saw was not secured to the plug.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Whitaker Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341817039.