TAMUNING, GU —
OSHA Inspection: WHITAKER CONSTRUCTION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WHITAKER CONSTRUCTION in 232 REDONDO DE FRANCISCO, TAMUNING, GU 96913 (NAICS 236115). OSHA activity number 341817039.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WHITAKER CONSTRUCTION
- Site address
- 232 REDONDO DE FRANCISCO
- City
- TAMUNING
- State
- GU
- ZIP
- 96913
- Mailing
- P.O. BOX 11092, YIGO, GU 96929
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.404 B01 I
- Issued
- Oct 18, 2016
- Penalty
- Initial $1,817 · Current $1,272 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. (a) On October 6, 2016, there was no assured equipment grounding conductor program or ground-fault circuit-interrupter protection when employees used a 110 VAC Milwaukee circular saw, powered through an extension cord.
Recent events (2)
- — I (S) $1271.9
- — Z (S) $1817
1926.404 F06
- Issued
- Oct 18, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: (a) On October 6, 2016, on the roof top, the path to ground on a 110 VAC non ground fault circuit interrupter receptacle used to supply power to a 50 foot green and red extension cord was not permanent and continuous.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Oct 18, 2016
- Penalty
- Initial $1,817 · Current $1,272 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On October 6, 2016, at the roof level, employees engaged in residential form were not protected by guardrail systems, safety net systems, or personal fall arrest systems. Employees were exposed to fall hazards.
Recent events (2)
- — I (S) $1271.9
- — Z (S) $1817
1926.1053 B01
- Issued
- Oct 18, 2016
- Penalty
- Initial $1,817 · Current $1,272 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On October 6, 2016, a 6 foot Werner aluminum stepladder used to gain access to the work area did not extend at least 3 feet above the landing, the ladder was not secured and there was no grab rail at the top of the landing.
Recent events (2)
- — I (S) $1271.9
- — Z (S) $1817
1926.405 G02 IV
- Issued
- Oct 18, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: (a) On October 6, 2016, at the project site, the outer insulation on the 50 foot red and green extension cord that supplied power to a Milwaukee circular saw was not secured to the plug.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Whitaker Construction
View Whitaker Construction's full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341817039.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.