Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MID-CONTINENTAL RESTORATION CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MID-CONTINENTAL RESTORATION CO., INC. in 1100 CONGRESS AVENUE, AUSTIN, TX 78701 (NAICS 238140). OSHA activity number 341821288.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mid-Continental Restoration CO., INC. — free Get an email when a new federal OSHA severe-injury report for Mid-Continental Restoration CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
1100 CONGRESS AVENUE
City
AUSTIN
State
TX
ZIP
78701
Mailing
4101 MURRAY AVENUE, FORT WORTH, TX 76117
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.502 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 17, 2016
Abate by
Oct 21, 2016
Penalty
Initial $8,017 · Current $4,810 Reduced
29 CFR 1926.502(a)(2): The employer did not provide and install all fall protection systems required by this subpart for employee(s) and did not comply with all other pertinent requirements of this subpart before employee(s) began the work that necessitates the fall protection.  On or about 6 October 2016, an employee used the fall protection system installed to perform tuck-point work on the ledge of a parapet wall without the employer determining the anchorage for such system to be capable of supporting at least 5,000 pounds per employee attached, exposing the employee to a fall hazard of approximately 150 feet to the concrete below.
Recent events (2)
  • — I (S) $4810.2
  • — Z (S) $8017

1926.502 D16 III

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 17, 2016
Abate by
Oct 21, 2016
Penalty
Initial $4,811 · Current $2,887 Reduced
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level.  On or about 6 October 2016, an employee performing tuck-point work was doing so at a height of approximately 150 feet on the ledge of a parapet wall with his personal fall arrest system attached to a fiber rope by a rope grab that was at his feet, allowing for a free fall of more than 6 feet and a pendulum effect, exposing the employee to the hazard of striking the wall below the parapet or swinging into the aerial lift nearby.
Recent events (2)
  • — I (S) $2886.6
  • — Z (S) $4811

View Mid-Continental Restoration CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341821288.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.