CHICAGO, IL —
OSHA Inspection: LOUIS MESKAN BRASS FOUNDRY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LOUIS MESKAN BRASS FOUNDRY, INC. in 2020 N. MAJOR AVE., CHICAGO, IL 60639 (NAICS 331523). OSHA activity number 341821692.
Where did this inspection happen?
- Establishment
- LOUIS MESKAN BRASS FOUNDRY, INC.
- Site address
- 2020 N. MAJOR AVE.
- City
- CHICAGO
- State
- IL
- ZIP
- 60639
- Mailing
- 2007-13 N. MAJOR AVE., CHICAGO, IL 60639
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331523
- Employees
- 105
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 I
- Issued
- Nov 23, 2016
- Abate by
- Dec 20, 2016
- Penalty
- Initial $6,413 · Current $5,200 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. a) On or about October 4, 2016, Louis Meskan Brass Foundry, Inc. did not ensure that an energy control procedure for the Harrison Core machine (Serial Number 585) was utilized when an employee was servicing the machine. In accordance with 29CFR 1903.19(d), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $5200
- — Z (S) $6413
1910.147 C04 II
- Issued
- Nov 23, 2016
- Abate by
- Dec 20, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items (a) through (d) of this section: a) On or about October 4, 2016, Louis Meskan Brass Foundry, Inc. did not ensure that there was an energy control procedure for the Harrison core machine (Serial number 585) that included the following items: a specific statement of the intended use (servicing, maintenance, and/or set up) of the procedure to lock out the Harrison Core machine, procedural steps to shut down the machine following the machine manual's turning off procedure, procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them for the electrical (main panel), pneumatic (rear of machine), thermal (rear of machine), and potential gravity (table) energy sources. In accordance with 29CFR 1903.19(d), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D
- Issued
- Nov 23, 2016
- Abate by
- Dec 20, 2016
- Penalty
- Initial $6,413 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) On or about October 4, 2016, an employee was exposed to machine hazards associated with moving parts during the servicing of the Harrison Core machine (Serial Number 585). The employee failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards. In accordance with 29CFR 1903.19(d), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $6413
1910.147 C06 I
- Issued
- Nov 23, 2016
- Abate by
- Dec 20, 2016
- Penalty
- Initial $4,811 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On October 6, 2016, Louis Meskan Brass Foundry, Inc. did not conduct a periodic inspection of the energy control procedure at least annually. In accordance with 29CFR 1903.19(d), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (O) $1000
- — Z (S) $4811
1910.147 C07 IV
- Issued
- Nov 23, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date: a) On October 6, 2016, Louis Meskan Brass Foundry, Inc. did not ensure that certify that employee training had been accomplished. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Louis Meskan Brass Foundry, INC.
View Louis Meskan Brass Foundry, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331523)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341821692.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.