SPARTA, IL —
OSHA Inspection: STORK'S MOWER SHOP LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of STORK'S MOWER SHOP LLC in 1037 ST. LOUIS ST, SPARTA, IL 62286 (NAICS 444210). OSHA activity number 341823508.
Where did this inspection happen?
- Establishment
- STORK'S MOWER SHOP LLC
- Site address
- 1037 ST. LOUIS ST
- City
- SPARTA
- State
- IL
- ZIP
- 62286
- Mailing
- 1037 ST. LOUIS ST, SPARTA, IL 62286
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444210
- Employees
- 3
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.212 A05
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: Shop Area, north side, the squirrel cage blower fan mounted onto a cart, did not have guards for the fan blades.
Recent events (1)
- — Z (S) $0
1910.219 E03 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): Shop area, north side, on the cart mounted squirrel cage fan, the belt drive was missing its guard.
Recent events (1)
- — Z (S) $0
1910.304 B03 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.304(b)(3)(i): All 125-volt, single-phase, 15- and 20-ampere receptacles installed in wet locations were not equipped with ground-fault circuit-interrupter protection for personnel: In the Restroom, the 110 volt electrical receptacle was not the GFCI type.
Recent events (1)
- — Z (S) $0
1910.305 A02 IX
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lamp holder with a guard: Throughout the Shop Area, the bulbs in the 17 fluorescent light assemblies were not protected from breakage by the use of assembly covers or bulb sleeves.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Shop Area, west wall to the outside shed area, a 110 volt extension cord was used to supply power to the outside area.
Recent events (1)
- — Z (S) $0
1910.334 A02 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: In the Shop area, on the Windermere pedestal fan, the cover over the inner electrical wiring was missing.
Recent events (1)
- — Z (S) $0
1910.141 D02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water: The water supply to the restroom was only cold water.
Recent events (1)
- — Z (O) $0
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: A written Hazard Communications program had not been developed to inform and train employees to protect them from chemical hazards while working with but not limited to motor oil, penetrating oil, and gasket maker.
Recent events (1)
- — Z (O) $0
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a safety data sheet for each hazardous chemical in use: The employer did not have safety data sheets for the hazardous chemicals such as, but not limited to motor oil, penetrating oil and gasket maker.
Recent events (1)
- — Z (O) $0
1910.1200 H02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(2)(i): The employer did not provide information to the employees on the requirements of the Hazard Communication Standard 29 CFR 1910.1200: Employees had not been trained regarding the use of hazardous chemicals such as but not limited to various motor oils, penetrating oil and gasket maker.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 444210)
HOUGHTON LAKE, MI—2026-05-07
UNIQUE GROUNDS & SUPPLY DBA OUTDOOR EQUIPMENT CO.
SAVAGE, MN—2026-04-21
111095 - MINNESOTA EQUIPMENT INC
ANAHEIM, CA—2026-03-17
B & M LAWN AND GARDEN, INC.
FAIRMOUNT CITY, PA—2026-03-17
LANDPRO EQUIPMENT LLC
FARMINGTON HILLS, MI—2026-03-10
WEINGARTZ SUPPLY COMPANY
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341823508.