Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CAMM METALS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CAMM METALS, INC. in 24 NEWBERRY ROAD, EAST WINDSOR, CT 06088 (NAICS 332322). OSHA activity number 341826253.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Camm Metals, INC. — free Get an email when a new federal OSHA severe-injury report for Camm Metals, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
CAMM METALS, INC.
Site address
24 NEWBERRY ROAD
City
EAST WINDSOR
State
CT
ZIP
06088
Mailing
P.O. BOX 539, EAST WINDSOR, CT 06088
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
10
Ownership type
A

8 citations on file for this inspection.

1910.253 B04 III

Serious Gravity 5 1 instance 10 exposed
Issued
Jan 9, 2017
Penalty
Initial $2,672 · Current $1,870 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  COMPRESSED GAS STORAGE AREA:  On or about, and at times prior to, October 11, 2016, a 56-inch oxygen cylinder was stored 18 inches from one propane cylinder and 32 inches from a cage containing another propane cylinder.  There was no non-combustible barrier separating the cylinders.
Recent events (2)
  • — I (S) $1870.4
  • — Z (S) $2672

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 9, 2017
Penalty
Initial $2,138 · Current $1,497 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  TIG WELDING AREA #2:  On or about, and at times prior to, October 11, 2016, a 24-inch Dayton Industrial Duty Air Circulator, Model 3C218F, being used in a TIG welding area was missing its ground pin.
Recent events (2)
  • — I (S) $1496.6
  • — Z (S) $2138

1910.1026 D01

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 9, 2017
Abate by
Feb 27, 2017
Penalty
Initial $1,604 · Current $1,123 Reduced
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI):  WELDING AREAS:  On or about, and at times prior to, October 11, 2016, the employer had not conducted exposure monitoring to determine whether employees who do MIG and TIG welding on stainless steel were exposed to hexavalent chromium (Cr6+).
Recent events (2)
  • — I (S) $1122.8
  • — Z (S) $1604

1910.1026 H02 II

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 9, 2017
Abate by
Feb 27, 2017
Penalty
Initial $1,604 · Current $1,123 Reduced
29 CFR 1910.1026(h)(2)(ii): The employer did not ensure that no employee removed chromium (VI)-contaminated protective clothing or equipment from the workplace, except for those employees whose job it was to launder, clean, maintain, or dispose of such clothing or equipment:  PRODUCTION AREAS:  On or about October 11, 2016, the employer allowed employees to wear their safety shoes and uniform pants home after welding stainless steel all day.
Recent events (2)
  • — I (S) $1122.8
  • — Z (S) $1604

1910.1026 I05

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 9, 2017
Abate by
Feb 27, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1026(i)(5): The employer did not ensure that employees did not eat, drink, smoke, chew tobacco or gum, or apply cosmetics in regulated areas, or in areas where skin or eye contact with chromium (VI) occurred; or carried the products associated with these activities, or stored such products in these areas:  WELDING AREAS:  On or about October 11, 2016, employees who were responsible for welding on stainless steel were allowed to drink coffee and other beverages in their work areas.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1026 J01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 9, 2017
Abate by
Feb 27, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1026(j)(1)(i): The employer did not ensure that all surfaces were maintained as free as practicable of accumulations of chromium (VI):  EMPLOYEE BREAK ROOM:  On or about November 3, 2016, wipe samples were collected on the countertop by the coffee machine and a table in the employee break room and submitted to the laboratory for analysis of hexavalent chromium (Cr6+).  The analytical results indicated that the surfaces were contaminated with Cr6+ thereby exposing all employees to the chemical.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1026 L01

Serious Gravity 1 1 instance 10 exposed
Issued
Jan 9, 2017
Abate by
Feb 27, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1026(l)(1): The employer did not ensure that all employees who were assigned to workplaces where there was exposure to chromium (VI) were provided with information and training as required by the Hazard Communication Standard 29 CFR 1910.1200:  COMPANY-WIDE:  On or about, and at times prior to, October 11, 2016, employees were exposed to hexavalent chromium as a result of welding on stainless steel and the employer did not provide them with any training in regards to the hazards of the chemical or what measures they should take to minimize exposure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C02 I

Other-than-serious 1 instance 2 exposed
Issued
Jan 9, 2017
Abate by
Feb 27, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  WELDING AREAS:  On or about, and at times prior to, October 11, 2016, the employer did not provide training to regarding the use of N-95 particulate respirators to employees who used the respirators on a voluntary basis while welding.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Camm Metals, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341826253.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.