Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ZINSMEYER MECHANICAL & WELDING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ZINSMEYER MECHANICAL & WELDING, INC. in 2891 US HIGHWAY 90 EAST, CASTROVILLE, TX 78009 (NAICS 238220). OSHA activity number 341831246.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Zinsmeyer Mechanical & Welding, INC. — free Get an email when a new federal OSHA severe-injury report for Zinsmeyer Mechanical & Welding, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2891 US HIGHWAY 90 EAST
City
CASTROVILLE
State
TX
ZIP
78009
Mailing
2891 US HIGHWAY 90 EAST, CASTROVILLE, TX 78009
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
52
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Other-than-serious 1 instance 4 exposed
Issued
Feb 6, 2017
Abate by
Feb 24, 2017
Penalty
Initial $8,873 · Current $6,211 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Coil line:  On or about October 6, 2016, and at times prior thereto, employees engaged in HVAC duct production using a hydraulic brake were exposed to caught-in hazards, while the machine had moving parts, which were not guarded to prevent contact.
Recent events (2)
  • — I (O) $6211
  • — Z (S) $8873

1910.219 C04 II

Other-than-serious 1 instance 4 exposed
Issued
Feb 6, 2017
Abate by
Feb 24, 2017
Penalty
Initial $6,338 · Current $4,436 Reduced
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered:    Coil line:  On or about October 11, 2016, and at times prior thereto, employees operating a coil line machine were exposed to caught-in hazards, while the machine had a rotating shaft which was not guarded to prevent contact.
Recent events (2)
  • — I (O) $4436
  • — Z (S) $6338

1910.305 B02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 6, 2017
Abate by
Mar 3, 2017
Penalty
Initial $5,070 · Current $3,549 Reduced
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose.  In completed installations, each outlet box did not have a cover, faceplate, or fixture canopy:      Coil line operating room: On or about October 11, 2016, and at times prior thereto, employees were exposed to electrical hazards while working near a receptacle outlet that had a missing cover plate; exposing electrical conductors.
Recent events (2)
  • — I (S) $3549
  • — Z (S) $5070

View Zinsmeyer Mechanical & Welding, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341831246.