OSHA Inspection: GENOA DEVELOPMENT, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GENOA DEVELOPMENT, LLC in 1720 NEW JERSEY AVE., NW, WASHINGTON, DC 20005 (NAICS 236116). OSHA activity number 341840593.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Genoa Development, LLC — free Get an email when a new federal OSHA severe-injury report for Genoa Development, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1720 NEW JERSEY AVE., NW
City
WASHINGTON
State
DC
ZIP
20005
Mailing
1534 5TH. ST., NW UNIT 2, WASHINGTON, DC 20001
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 2 instances 2 exposed
Issued
Dec 29, 2016
Abate by
Jan 9, 2017
Penalty
Initial $3,741 · Current $3,741
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:    a)  Front of Building, Second Floor - On or about October 11, 2016, masons were exposed to an 18 foot fall from an unguarded open-sided floor.  b)  First Floor - On or about October 11, 2016, workers were exposed to an 8 foot 7 inch fall  at an unguarded open-sided floor.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $3741

1926.501 B04 I

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 29, 2016
Abate by
Jan 9, 2017
Penalty
Initial $2,672 · Current $2,672
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around the hole:   a)  Front of Building, First Floor -  On or about October 11, 2016, workers were exposed to an 8 foot 7 inch fall through a 5 foot by 5 foot floor opening which had been left uncovered.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $2672

1926.501 B06

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 29, 2016
Abate by
Jan 9, 2017
Penalty
Initial $2,138 · Current $2,138
29 CFR 1926.501(b)(6): Each employee on ramps, runways, and other walkways was not protected from falling 6 feet (1.8 m) or more to lower levels by guardrail systems:   a)  Front of Building, Ramp - On or about October 11, 2016, laborers were exposed to an 8 ft. 7 in. fall from a ramp they were walking across to enter and exit a building which had not been provided with fall protection.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $2138

1926.501 B14

Serious Gravity 10 3 instances 6 exposed
Issued
Dec 29, 2016
Abate by
Jan 9, 2017
Penalty
Initial $3,741 · Current $3,741
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system:    a)  Second Floor  - On or about October 11, 2016, workers were exposed to a 20 foot fall from a 38 inch wide wall opening which was not provided with fall protection.  b)  Second Floor  - On or about October 11, 2016, workers were exposed to a 20 foot fall from a 7 foot wide wall opening which was not provided with fall protection.    c )  Second Floor  - On or about October 11, 2016, workers were exposed to an 18 foot fall from a 52 inch wide wall opening which was not provided with fall protection.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $3741

1926.501 C

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 29, 2016
Abate by
Jan 5, 2017
Penalty
Initial $3,207 · Current $3,207
29 CFR 1926.501(c)(1): When an employee was exposed to falling objects, the employer did not have each employee wear a hard hat and did not erect toe boards, screens, or guardrail systems to prevent objects from falling from higher levels  a)  Front of Building, First Floor - On or about October 11, 2016, laborers delivering building materials into a building were exposed to a struck-by hazard while walking under an active masonry operation and were not wearing hard hats and falling object protection was not provided.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $3207

View Genoa Development, LLC's full OSHA safety record →