WASHINGTON, DC —
OSHA Inspection: GENOA DEVELOPMENT, LLC
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of GENOA DEVELOPMENT, LLC in 1720 NEW JERSEY AVE., NW, WASHINGTON, DC 20005 (NAICS 236116). OSHA activity number 342196573.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GENOA DEVELOPMENT, LLC
- Site address
- 1720 NEW JERSEY AVE., NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20005
- Mailing
- 1534 5TH. ST., NW UNIT 2, WASHINGTON, DC 20001
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 1
- Ownership type
- A
Citations
6 citations on file for this inspection.
1903.19 C01
- Issued
- Jul 20, 2018
- Abate by
- Aug 15, 2018
- Penalty
- Initial $311 · Current $311
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a) Genoa Development, LLC - On or about July 18, 2018, the employer did not provide abatement certification for citation 1, Item 3 group a, 29 CFR 1926.451(b)(3) issued on 06/20/2017 with a final order date of 09/05/2017. b) Genoa Development, LLC - On or about July 18, 2018, the employer did not provide abatement certification for citation 1, Item 3 group b, 29 CFR 1926.451(g)(1)(i) issued on 06/20/2017 with a final order date of 09/05/2017.
Recent events (1)
- — Z (O) $311
1926.1052 B02
- Issued
- Jun 20, 2017
- Abate by
- Jun 26, 2017
- Penalty
- Initial $3,585 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.1052(b)(2): Foot traffic was not prohibited on skeleton metal stairs where permanent treads and/or landings were to be installed at a later date and the stairs were not fitted with secured temporary treads and/or landings long enough to cover the entire tread or landing area: a) Landings, Stairway No. 1 On or about March 21, 2017, the 7 foot 2 inch by 3 foot 9 inch pan stair landings in a stairway, which were not under construction and provided for temporary use, were not fitted with temporary landings thereby exposing workers to a potential 10 ft. fall hazard. b) Landings, Stairway No. 2 On or about March 21, 2017, the 7 foot 2 inch by 3 foot 9 inch pan stair landings in a stairway, which were not under construction and provided for temporary use, were not fitted with temporary landings thereby exposing workers to a potential 10 ft. fall hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- — F (S) $2000
- — C (S) $3585
- — Z (S) $3585
1926.1052 C01 I
- Issued
- Jun 20, 2017
- Abate by
- Jun 26, 2017
- Penalty
- Initial $3,585 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) Stairway No. 1 On or about March 21, 2017, flights of metal stairs, having at least nine risers and which ran between four floors of a building under construction, were not provided with handrails thereby exposing workers to a potential 10 ft. fall hazard. b) Stairway No. 2 On or about March 21, 2017, flights of metal stairs, having at least nine risers, and which ran between four floors of a building under construction, were not provided with handrails thereby exposing workers to a potential 10 ft. fall hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- — F (S) $2100
- — C (S) $3585
- — Z (S) $3585
1926.1052 C01 II
- Issued
- Jun 20, 2017
- Abate by
- Jun 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) Stairway No. 1 On or about March 21, 2017, flights of metal stairs, having at least nine risers and which ran between four floors of a building under construction, were not provided with stairrails on all open sides thereby exposing workers to a potential 10 ft. fall hazard. b) Stairway No. 2 On or about March 21, 2017, flights of metal stairs, having at least nine risers and which ran between four floors of a building under construction, were not provided with stairrails on all open sides thereby exposing workers to a potential 10 ft. fall hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.451 B03
- Issued
- Jun 20, 2017
- Abate by
- Jun 26, 2017
- Penalty
- Initial $4,183 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.451(b)(3): The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling: a) Atrium On or about March 21, 2017, two workers installing sheathing and insulation boards from the 12 inch wide platform of a pump jack scaffold were exposed to a 40 foot fall for their work platform was located 21 inches (horizontally) away from the wall surface they were working upon. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $2500
- — C (S) $4183
- — Z (S) $4183
1926.451 G01 I
- Issued
- Jun 20, 2017
- Abate by
- Jun 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) Atrium On or about March 21, 2017, four workers installing sheathing and insulation boards from the platform of a pump jack scaffold were not provided with personal fall protection and were exposed to a 40 foot fall. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at Genoa Development, LLC
View Genoa Development, LLC's full OSHA safety record →
More inspections in this industry (NAICS 236116)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342196573.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.