Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMPHENOL THERMOMETRICS, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of AMPHENOL THERMOMETRICS, INC. in 967 WINDFALL ROAD, SAINT MARYS, PA 15857 (NAICS 334416). OSHA activity number 341853695.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Amphenol Thermometrics, INC. — free Get an email when a new federal OSHA severe-injury report for Amphenol Thermometrics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
967 WINDFALL ROAD
City
SAINT MARYS
State
PA
ZIP
15857
Mailing
967 WINDFALL ROAD, SAINT MARYS, PA 15857
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334416
Employees
200
Ownership type
A

4 citations on file for this inspection.

1910.303 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 18, 2017
Penalty
Initial $5,233 · Current $3,417 Reduced
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:       a.) Amphenol Thermometrics, Inc., 967 Windfall Rd. St. Marys, PA, Die craft loader area next to Dip solder machine #2595- on or about October 19th, 2016 and times prior thereto:  Employees utilized a foot pedal in order to operate a die craft loading machine onsite.  The conduit protecting the internal wiring of the foot pedal was disconnected/split exposing the internal wires associated with the foot pedal.
Recent events (2)
  • — I (S) $3417
  • — Z (S) $5233

1910.303 G01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:    a.) Amphenol Thermometrics, Inc., 967 Windfall Rd. St. Marys, PA, Diode plating area, on or about October 19th, 2016 and times prior thereto:  Items including, but not limited to, a chemical spill kit cabinet, and cardboard drum of Mirapic ME-815 were stored directly in front of a 120/240 electrical panel box.  The employer did not ensure the area in front of the electrical panel box was kept clear for access.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1025 L01 I

Other-than-serious 1 instance 1 exposed
Issued
Jan 18, 2017
Abate by
Feb 13, 2017
Penalty
Initial $6,157 · Current $3,417 Reduced
29 CFR 1910.1025(l)(1)(i): Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025:     a.) Amphenol Thermometrics, Inc., 967 Windfall Rd. St. Marys, PA, Dip-Solder machine #2595, on or about October 19th, 2016 and times prior thereto:  An employee worked with and around lead based metal alloys during dip-soldering operations of parts onsite.  The employee who worked with and around lead based metals was not provided with training on the contents of Appendices A and B of 29 CFR 1910.1025.
Recent events (2)
  • — I (O) $3417
  • — Z (S) $6157

1910.1025 G01 II

Other-than-serious 1 instance 1 exposed
Issued
Jan 18, 2017
Abate by
Feb 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(g)(1)(ii):  Employee(s) working in an area where there is the possibility of skin irritation from lead exposure were not required to wear gloves during all work operations with lead:        a.)    Amphenol Thermometrics, Inc., 967 Windfall Rd. St. Marys, PA, Dip-Solder machine #2595, on or about October 19th, 2016 and times prior thereto:  An employee worked with and around lead based metal alloys during dip-soldering operations of parts onsite.  The employee was not required to use gloves during the handling and cleaning operations of lead in and around the Dip-Solder machine #2595.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341853695.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.