Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TYCO ELECTRONICS CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of TYCO ELECTRONICS CORPORATION in 1590 KAUFFMAN ROAD, LANDISVILLE, PA 17538 (NAICS 334417). OSHA activity number 341855237.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tyco Electronics Corporation — free Get an email when a new federal OSHA severe-injury report for Tyco Electronics Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1590 KAUFFMAN ROAD
City
LANDISVILLE
State
PA
ZIP
17538
Mailing
1590 KAUFFMAN ROAD, LANDISVILLE, PA 17538
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334417
Employees
160
Ownership type
A

4 citations on file for this inspection.

1910.37 A02

Deleted Serious Gravity 5 1 instance 21 exposed
Issued
Nov 30, 2016
Penalty
Initial $8,017 · Current $0 Reduced
29 CFR 1910.37(a)(2): Exit routes were not arranged so that employees did not have to travel toward a high hazard area, unless the path of travel was effectively shielded from the high hazard area by suitable partitions or other physical barriers:  (a) Production Area; Women's Locker Room - The door leading to the Stamping Department was blocked from use leaving only one exit route door leading to the aisle adjacent to the Plating Department where hazardous chemicals, such as sodium cyanide, were used, on or about October 21, 2016.  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8017

1910.37 A03

Other-than-serious 1 instance 21 exposed
Issued
Nov 30, 2016
Penalty
Initial $0 · Current $4,811
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    (a) Production Area; Women's Locker Room -  An exit sign was located over the door leading into the locker room from the Plating Department, but the second door from the locker room leading into the Stamping Department was barred and unavailable for use as an exit route, on or about October 21, 2016.      No abatement certification or documentation required.
Recent events (2)
  • — I (O) $4811
  • — Z (S) $0

1910.37 B05

Other-than-serious 1 instance 21 exposed
Issued
Nov 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):    (a) Production Area; Women's Locker Room - The door leading from the locker room and into the Stamping Department was not marked with "Not an Exit" sign after the exit route was removed from use, on or about October 21, 2016.    No abatement certification or documentation required.    MODIFIED DUE TO ISA ON 12/20/16     avd modified to the sign marked not an exiton the door leading from the locker room and into the Stamping Department was removed without managements knowledge on or about October 21, 2016.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.120 Q02 XI

Deleted Other-than-serious 1 instance 160 exposed
Issued
Nov 30, 2016
Abate by
Jan 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.120(q)(2)(xi): The emergency response plan did not address, to the extent not addressed elsewhere, personal protective equipment (PPE) and emergency equipment:  (a) Tyco Electronics Corporation dba TE Connectivity - The employer's Emergency Response Plan did not include information on the personal protective equipment available for emergency response use, as well as instructions for the use of the personal protective equipment, on or about October 25, 2016.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Tyco Electronics Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341855237.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.