OSHA Inspection: AVONCE CONSTRUCTION GROUP INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AVONCE CONSTRUCTION GROUP INC in 6710 SOUTH FLORIDA AVENUE, LAKELAND, FL 33813 (NAICS 238130). OSHA activity number 341857902.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Avonce Construction Group INC — free Get an email when a new federal OSHA severe-injury report for Avonce Construction Group INC is published. One employer, no account, unsubscribe in one click.
Site address
6710 SOUTH FLORIDA AVENUE
City
LAKELAND
State
FL
ZIP
33813
Mailing
1970 E. OSCEOLA PKWY #318, KISSIMMEE, FL 34743
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
1
Ownership type
A

2 citations on file for this inspection.

1926.501 B11

Serious Gravity 10 1 instance 5 exposed
Issued
Jan 12, 2017
Penalty
Initial $8,730 · Current $2,993 Reduced
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:    a) For sub contractor employees working at 6710 South Florida Avenue in Lakeland as observed on or about October 18, 2016. Sub contractor employees were working on the 8:12 pitch steep roof installing roof sheathing without the use of a personal fall arrest system. Employees were exposed to an approximate 42 foot fall.
Recent events (2)
  • — I (S) $2993.04
  • — Z (S) $8730

1926.502 D15

Serious Gravity 10 2 instances 3 exposed
Issued
Jan 12, 2017
Penalty
Initial $8,730 · Current $2,993 Reduced
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person.    For subcontractor's employees working at 6710 South Florida Avenue in Lakeland as observed on or about 18 October, 2016.       a) Employees were working on the fourth floor roof while using personal fall arrest equipment without an anchor point. The employees wrapped the lifeline around the stub of a framing member for the truss and connected to itself. The employees were exposed to a fall height of approximately 41 feet 6.75 inches.      b) Employees were working on the third floor balcony while using personal fall arrest equipment without an anchor point. The employees wrapped a lanyard around a framing wall stud and connected to itself. The employees were exposed to a fall height of approximately 21 feet 8.5 inches.