Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TOWER ENERGY INTERNATIONAL, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TOWER ENERGY INTERNATIONAL, LLC in 144 LAKE SHORE DR., RACINE, WI 53403 (NAICS 238160). OSHA activity number 341861268.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tower Energy International, LLC — free Get an email when a new federal OSHA severe-injury report for Tower Energy International, LLC is published. One employer, no account, unsubscribe in one click.
Site address
144 LAKE SHORE DR.
City
RACINE
State
WI
ZIP
53403
Mailing
2425 S. MEMORIAL DR., RACINE, WI 53403
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

6 citations on file for this inspection.

1910.1200 E01

Other-than-serious 1 instance 2 exposed
Issued
Dec 15, 2016
Abate by
Jan 12, 2017
Penalty
Initial $2,138 · Current $0 Reduced
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):    (a) The employer did not ensure that a hazard communication program was implemented in the company.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2138

1910.1200 F01

Other-than-serious 1 instance 2 exposed
Issued
Dec 15, 2016
Abate by
Jan 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(1): The chemical manufacturer, importer, or distributor did not ensure that each container of classified hazardous chemicals leaving the workplace was labeled, tagged or marked with the information required in 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(vi)    (a) The employer did not ensure that a substance used for roof coating was labeled, tagged or marked.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.1200 G08

Other-than-serious 1 instance 2 exposed
Issued
Dec 15, 2016
Abate by
Feb 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s)    (a) The employer did not maintain safety data sheets for a roof coating used on a commercial roof.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.1200 H01

Other-than-serious 1 instance 2 exposed
Issued
Dec 15, 2016
Abate by
Jan 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    (a) The employer did not ensure that employees received training in hazardous chemicals.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.501 B10

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 15, 2016
Abate by
Dec 21, 2016
Penalty
Initial $4,988 · Current $4,988
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.    (a) The employer did not ensure that employees were using fall protection when conducting roofing work on a commercial building.
Recent events (2)
  • — I (S) $4988
  • — Z (S) $4988

1926.503 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 15, 2016
Abate by
Jan 12, 2017
Penalty
Initial $3,563 · Current $0 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:    (a) The employer did not ensure that employees were trained in recognizing fall hazards and implementing fall protection when conducting roofing work on a commercial building.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3563

View Tower Energy International, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341861268.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.