Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QSR STEEL CORPORATION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of QSR STEEL CORPORATION, LLC in 100 MAIN STREET, WINSTED, CT 06063 (NAICS 238120). OSHA activity number 341865806.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch QSR Steel Corporation, LLC — free Get an email when a new federal OSHA severe-injury report for QSR Steel Corporation, LLC is published. One employer, no account, unsubscribe in one click.
Site address
100 MAIN STREET
City
WINSTED
State
CT
ZIP
06063
Mailing
300 LOCUST STREET, HARTFORD, CT 06114
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
4
Ownership type
A

5 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 4 exposed
Issued
Jan 24, 2017
Abate by
Feb 10, 2017
Penalty
Initial $406 · Current $406
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:    On or about January 24, 2017, the employer had not provided any documentation that the violations previously cited had been corrected.
Recent events (3)
  • — C (O) $406
  • — F (O) $406
  • — Z (O) $406

1926.503 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 18, 2016
Abate by
Dec 1, 2016
Penalty
Initial $3,920 · Current $581 Reduced
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.    a)  Joyner Hall Job Site - On or about 10-26-16 - The employer did not provide a certification record that employees were trained in the proper use and selection of fall protection systems while working from a JLG aerial lift.
Recent events (3)
  • — C (S) $3920
  • — F (S) $580.5
  • — Z (S) $3920

1926.760 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 18, 2016
Penalty
Initial $3,920 · Current $581 Reduced
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems.    a)  Joyner Hall Job Site - On or about 10-26-16 - Employees were exposed to twenty-two foot fall hazard while working on a metal decked area with access to parapet wall thirty inches in height which did not provided adequate fall protection in the work area.
Recent events (3)
  • — C (S) $3920
  • — F (S) $580.5
  • — Z (S) $3920

1926.95 B

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 18, 2016
Abate by
Dec 1, 2016
Penalty
Initial $7,839 · Current $7,839
29 CFR 1926.95(b): Where employees provide their own protective equipment, the employer did not assure its adequacy, including proper maintenance, and sanitation of such equipment:    a)  Joyner Hall Job Site - On or about 10-26-16 - Employees working from an aerial lift exposed to fall hazards were using a fall protection system which would allow them to contact a lower level.
Recent events (3)
  • — C (R) $7839
  • — F (S) $7839
  • — Z (R) $7839

1926.502 D16 III

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 18, 2016
Abate by
Dec 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:    a)  Joyner Hall Job Site - On or about 10-26-16 - Employees were exposed to fall hazards of six to twenty feet while working from a JLG aerial lift.  Employees were using six foot shock absorbing lanyards that would allow contact with lower levels.
Recent events (3)
  • — C (R) $0
  • — F (S) $0
  • — Z (R) $0

View QSR Steel Corporation, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341865806.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.