Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INTERTAPE POLYMER GROUP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of INTERTAPE POLYMER GROUP in 1095 S. 4TH AVE, BRIGHTON, CO 80601 (NAICS 322221). OSHA activity number 341868966.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Intertape Polymer Group — free Get an email when a new federal OSHA severe-injury report for Intertape Polymer Group is published. One employer, no account, unsubscribe in one click.
Site address
1095 S. 4TH AVE
City
BRIGHTON
State
CO
ZIP
80601
Mailing
1095 S. 4TH AVE, BRIGHTON, CO 80601
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322221
Employees
38
Ownership type
A

6 citations on file for this inspection.

1910.146 C01

Serious Gravity 1 1 instance 4 exposed
Issued
Jan 27, 2017
Abate by
Apr 16, 2017
Penalty
Initial $4,617 · Current $3,878 Reduced
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:     (a)  Intertape Polymer Group, 1095 S. 4th Avenue, Brighton, CO:  On and before October 13th, 2016, the employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces. This condition exposed employees to potential physical and/or atmospheric hazards while entering the Machine Direction Orienter (MDO).
Recent events (2)
  • — I (S) $3878
  • — Z (S) $4617

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 27, 2017
Abate by
Apr 16, 2017
Penalty
Initial $12,675 · Current $10,647 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:     (a)  Intertape Polymer Group, 1095 S. 4th Avenue, Brighton, CO: On and before October 24th, 2016, the employer had not developed specific procedures to ensure that before employees enter the Machine Direction Orienter (MDO) for the purpose of removing torn and defective film product, all hazardous energy including but not limited to electrical, thermal heat, and in-running nip points were isolated and rendered inoperative. On or about October 13, 2016, an employee was seriously injured after entering the MDO machine for the purpose of removing a film tear out between energized "in-running" nip rollers. The employees right hand and forearm was crushed and subsequently amputated after being caught between two energized "in-running" nip rollers.
Recent events (2)
  • — I (S) $10647
  • — Z (S) $12675

1910.147 C06 I

Serious Gravity 10 1 instance 38 exposed
Issued
Jan 27, 2017
Abate by
Apr 16, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:       (a)  Intertape Polymer Group, 1095 S. 4th Avenue, Brighton, CO: On and prior to October 25th, 2016, the employer had not conducted periodic inspections of all energy control procedures including but not limited to the Machine Direction Orienter (MDO) to ensure all energy sources capable of causing injury are isolated and rendered inoperative prior to servicing and or maintenance.     Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Sample Abatement-Certification Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 27, 2017
Abate by
Apr 16, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:    (a)  Intertape Polymer Group, 1095 S. 4th Avenue, Brighton, CO: On and prior to October 13, 2016, the employer did not ensure employees required to enter the Machine Direciton Orienter (MDO) for the purpose of removing torn and defective film product were trained in lockout/tagout specific to the Machine Direction Orienter (MDO).  As a result, an employees right hand and forearm was crushed and subsequently amputated after being caught between two energized "in-running" nip rollers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 2 instances 10 exposed
Issued
Jan 27, 2017
Abate by
Apr 16, 2017
Penalty
Initial $7,695 · Current $6,475 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazards created by ingoing nip points:     (a)  Intertape Polymer Group, 1095 S. 4th Avenue, Brighton, CO:  On and before October 13th, 2016, the ingoing nip points on the entry feed roller outside the Machine Direction Orienter (MDO) were not guarded to prevent employee from inadvertent contact.   Condition exposed employees to amputation hazards.     (b)  Intertape Polymer Group, 1095 S. 4th Avenue, Brighton, CO:  On and before October 13th, 2016, the ingoing nip points on the exit feed roller outside the Machine Direction Orienter (MDO) were not guarded to prevent employee from inadvertent contact.   Condition exposed employees to amputation hazards.
Recent events (2)
  • — I (S) $6475
  • — Z (S) $7695

1910.132 D02

Other-than-serious 1 instance 38 exposed
Issued
Jan 27, 2017
Abate by
Mar 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment:   (a)  Intertape Polymer Group, 1095 S. 4th Avenue, Brighton, CO:  On and before October 13th, 2016, the employer did not have written certification that a comprehensive hazard assessment was completed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Intertape Polymer Group's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341868966.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.