Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SAETEROS CONSTRUCTION, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SAETEROS CONSTRUCTION, LLC in 1218 CHESTNUT ST, PHILADELPHIA, PA 19107 (NAICS 236220). OSHA activity number 341872018.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Saeteros Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Saeteros Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1218 CHESTNUT ST
City
PHILADELPHIA
State
PA
ZIP
19107
Mailing
700 WEST CHESTER PIKE, HAVERTOWN, PA 19083
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
2
Ownership type
A

6 citations on file for this inspection.

1926.451 F15

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 29, 2016
Penalty
Initial $3,527 · Current $3,527
29 CFR 1926.451(f)(15): Ladders were used on scaffolds to increase the working level height of employees.  a)  The Bailey Building:  On or about 10/20/16, employees were using a 6 foot stepladder placed on top of a fabricated frame scaffold approximately 6 feet high exposing employees to fall hazards.
Recent events (1)
  • — Z (S) $3527

1926.454 A03

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 29, 2016
Abate by
Dec 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a)(3): The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the proper use of the scaffold, and the proper handling of materials on the scaffold.   a)  The Bailey Building - On or about 10/20/16, the employer did not have each employee trained to recognize hazards associated with performing work from a fabricated frame scaffold.
Recent events (1)
  • — Z (S) $0

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 29, 2016
Abate by
Dec 5, 2016
Penalty
Initial $2,886 · Current $2,886
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purpose for which they were designed:  a)    The Bailey Building - On or about 10/20/16, an 8-foot stepladder, designed to be used in the open and braced position, was left in the closed position while an employee utilized it to access the working level of a 6-foot high fabricated frame scaffold exposing employees to fall hazards.
Recent events (1)
  • — Z (S) $2886

1926.1060 A01 III

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 29, 2016
Abate by
Dec 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a)(1)(iii): The employer did not ensure that each employee using ladders and stairways had been trained by a competent person in the proper construction, use, placement, and care in handling of all stairways and ladders:  a)  The Bailey Building - On or about 10/20/16, the employer did not have each employee trained in the proper use of the ladders being used.
Recent events (1)
  • — Z (S) $0

1926.416 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 29, 2016
Abate by
Dec 16, 2016
Penalty
Initial $4,115 · Current $4,115
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  a)  The Bailey Building - On or about 10/20/16, the employer allowed employees to remove energized components of store sign exposing employees to shock and electrocution hazards.
Recent events (1)
  • — Z (S) $4115

1926.1053 B01

Repeat Gravity 5 1 instance 2 exposed
Issued
Nov 29, 2016
Abate by
Dec 16, 2016
Penalty
Initial $7,055 · Current $7,055
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  a)  The Bailey Building - On or about 10/20/16, Employee(s) were utilizing an 8-foot portable stepladder to access the 6-foot high surface of a fabricated frame scaffold.  The ladder did not extend at least 3 feet past the landing and was not provided with a grab rail exposing employees to fall hazards.  Saeteros Construction, LLC was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1094041, citation number 1, item number 3, and was affirmed as a final order on 5/16/16, with respect to a workplace located at1111 S State St, Ephrata, PA.
Recent events (1)
  • — Z (R) $7055

View Saeteros Construction, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341872018.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.