Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CANAM STEEL CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CANAM STEEL CORPORATION in 2000 W. MAIN ST., WASHINGTON, MO 63090 (NAICS 332312). OSHA activity number 341883221.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Canam Steel Corporation — free Get an email when a new federal OSHA severe-injury report for Canam Steel Corporation is published. One employer, no account, unsubscribe in one click.
Site address
2000 W. MAIN ST.
City
WASHINGTON
State
MO
ZIP
63090
Mailing
2000 W. MAIN ST., WASHINGTON, MO 63090
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
165
Ownership type
A

3 citations on file for this inspection.

1910.147 C07 I B

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 17, 2016
Abate by
Dec 14, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(B): Each affected employee shall be instructed in the purpose and use of the energy control procedure:  On 11/01/2016 or about, all employees were not trained in the companys LO/TO Program at Canam Steel Corporation located at 2000 W. Main St., Washington, MO 63090.  Affected employee(s) were missing their training.
Recent events (1)
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 5 1 instance 7 exposed
Issued
Nov 10, 2016
Abate by
Dec 8, 2016
Penalty
Initial $8,908 · Current $8,908
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.  Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance:  On 11/01/2016 or about, the LO/TO procedure(s) at Canam Steel Corporation located at 2000 W. Main St., Washington, MO 63090, were missing steps and/or was too vague to understand the necessary procedure(s).
Recent events (1)
  • — Z (S) $8908

1910.212 A02

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 10, 2016
Abate by
Dec 8, 2016
Penalty
Initial $12,471 · Current $12,471
29 CFR 1910.212(a)(2): General requirements for machine guards. Guards shall be affixed to the machine where possible and secured elsewhere if for any reason attachment to the machine is not possible. The guard shall be such that it does not offer an accident hazard in itself:   On 10/28/2016 or about, at Canam Steel Corporation located at 2000 W. Main St., Washington, MO 63090, the guarding on the W1 Bottom Chord Shear did not have all their guards permanently affixed to the machine. One particular guard could be removed by lifting by hand (no tools required).  This particular guard was removed from position and an incident occurred which caused a hospitalization with surgery.   Other guards that were designed to be opened had limited switches which were not activated on the day of the incident (10/28/2016).
Recent events (1)
  • — Z (S) $12471

View Canam Steel Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341883221.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.