OSHA Inspection: MACRI ROOFING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MACRI ROOFING, INC. in 22 BUTTON STREET, MERIDEN, CT 06450 (NAICS 238160). OSHA activity number 341887248.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Macri Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for Macri Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MACRI ROOFING, INC.
Site address
22 BUTTON STREET
City
MERIDEN
State
CT
ZIP
06450
Mailing
36 DUFFY AVENUE P.O. BOX 712, MERIDEN, CT 06451
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
1
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Jan 6, 2017
Abate by
Jan 19, 2017
Penalty
Initial $4,988 · Current $0 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   JOBSITE:  The employees, performing residential roofing work on a 4 in 12 pitched roof were not protected from falling between 9 feet 2 inches to 16 feet 3 inches to the ground by the use of guardrails, personal fall arrest system, or other equivalent means.
Recent events (3)
  • — F (S) $0
  • — C (S) $4988
  • — Z (S) $4988

1926.1053 B01

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jan 6, 2017
Abate by
Jan 19, 2017
Penalty
Initial $3,563 · Current $0 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  JOBSITE:  The side rails of the Little Giant Ladder used by employees to access the roof of a house did not extend at least 3 feet above the upper landing surface.
Recent events (3)
  • — F (S) $0
  • — C (S) $3563
  • — Z (S) $3563

1926.1053 B10

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jan 6, 2017
Abate by
Jan 19, 2017
Penalty
Initial $3,563 · Current $0 Reduced
29 CFR 1926.1053(b)(10): The tops of a non-self-supporting ladder with more than one support attachment were not placed with the two rails supported equally:  JOBSITE:  The tops of the side rails of the Little Giant Ladder used by employees to access the roof were not supported equally on the surface of the roof where the ladder was leaning.
Recent events (3)
  • — F (S) $0
  • — C (S) $3563
  • — Z (S) $3563