Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RUBEN GONZALEZ

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of RUBEN GONZALEZ in 17 WASHINGTON STREET, KEENE, NH 03431 (NAICS 238160). OSHA activity number 341893055.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ruben Gonzalez — free Get an email when a new federal OSHA severe-injury report for Ruben Gonzalez is published. One employer, no account, unsubscribe in one click.
Establishment
RUBEN GONZALEZ
Site address
17 WASHINGTON STREET
City
KEENE
State
NH
ZIP
03431
Mailing
52 MANDALAY ROAD, SPRINGFIELD, MA 01118
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 5 exposed
Issued
Mar 6, 2017
Abate by
Mar 10, 2017
Penalty
Initial $3,803 · Current $2,000 Reduced
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:     a. Roof- Employees working from the upper roof were exposed to a fall of approximately 33 feet where personal fall arrest systems or a combination of a warning line system and safety monitoring system was not used while installing a rubber membrane roof.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3803

1926.503 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 6, 2017
Abate by
Mar 23, 2017
Penalty
Initial $2,716 · Current $0 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:    a. Roof- Employees working from the upper roof who were exposed to a fall of approximately 33 feet were not provided fall protection training from the employer.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2716

1926.1051 A

Serious Gravity 1 1 instance 5 exposed
Issued
Mar 6, 2017
Abate by
Mar 10, 2017
Penalty
Initial $1,630 · Current $800 Reduced
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided:    a. Site- Employees using a door opening in the building to access the low roof were not protected from a fall hazard where the opening was 29 inches off of the floor and there was no stair to access the opening.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1630

View Ruben Gonzalez's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341893055.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.