Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ANACONDA FOUNDRY FABRICATION COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ANACONDA FOUNDRY FABRICATION COMPANY, INC. in 1015 EAST 6TH STREET, ANACONDA, MT 59711 (NAICS 331511). OSHA activity number 341895365.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Anaconda Foundry Fabrication Company, INC. — free Get an email when a new federal OSHA severe-injury report for Anaconda Foundry Fabrication Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1015 EAST 6TH STREET
City
ANACONDA
State
MT
ZIP
59711
Mailing
1015 EAST 6TH STREET, ANACONDA, MT 59711
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
75
Ownership type
A

7 citations on file for this inspection.

1910.37 B06

Serious Gravity 1 3 instances 75 exposed
Issued
Feb 6, 2017
Abate by
Mar 3, 2017
Penalty
Initial $3,231 · Current $1,939 Reduced
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:     a) The Foundry:  On November 01, 2016 and at times prior, employees were exposed to entrapment hazards while conducting casting operations without a visible fire exit. The employer failed to provide an exit sign illuminated with at least five foot-candles (54 lux) by a reliable light source or distinctive in color.     b) The West Fab Shop: On November 01, 2016 and at times prior, employees were exposed to entrapment hazards while welding, cutting, grinding, and fabricating without a visible fire exit. The employer failed to provide an exit sign illuminated with at least five foot-candles (54 lux) by a reliable light source or distinctive in color.     c) The Main Fab Shop: On November 01, 2016 and at times prior, employees were exposed to entrapment hazards while welding, cutting, grinding, and fabricating without a visible fire exit. The employer failed to provide an exit sign illuminated with at least five foot-candles (54 lux) by a reliable light source or distinctive in color.
Recent events (2)
  • — I (S) $1938.6
  • — Z (S) $3231

1910.212 A01

Serious Gravity 5 4 instances 10 exposed
Issued
Feb 6, 2017
Abate by
Mar 3, 2017
Penalty
Initial $4,310 · Current $2,586 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:        a) The West Fab Shop:  On November 01, 2016 and at times prior, employees were exposed to caught in hazards from the rotating parts while using the unguarded jet drill press (Model #200705).     b) The West Fab Shop: On November 01, 2016 and at times prior, employees were exposed to flying chips and objects while pressing fittings in the unguarded hydraulic press break.       c) The Foundry:  On November 01, 2016 and at times prior, employees were exposed to ingoing nip points from the unguarded drive wheel on the slinger machine.
Recent events (2)
  • — I (S) $2586
  • — Z (S) $4310

1910.215 A04

Serious Gravity 1 1 instance 5 exposed
Issued
Feb 6, 2017
Abate by
Mar 3, 2017
Penalty
Initial $3,231 · Current $1,939 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:        a) The West Fab Shop:  On November 01, 2016 and at times prior, employees were exposed to being pulled into the Dayton bench grinder while using a work rest adjusted to approximately three eighths of an inch.
Recent events (2)
  • — I (S) $1938.6
  • — Z (S) $3231

1910.215 B09

Serious Gravity 1 1 instance 5 exposed
Issued
Feb 6, 2017
Abate by
Mar 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:        a) The West Fab Shop:  On November 01, 2016 and at times prior, employees were exposed to being struck by pieces of the abrasive wheel in the event of a fracture while using a Dayton bench grinder with a tongue guard adjusted to approximately one and one half of an inch.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 75 exposed
Issued
Feb 6, 2017
Abate by
Mar 3, 2017
Penalty
Initial $4,310 · Current $2,586 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.    a) The West Fab Shop:  On November 01, 2016 and at times prior, employees were exposed to fire hazards while working in and around oxygen bottles stored approximately 36 inches from acetylene bottles.
Recent events (2)
  • — I (S) $2586
  • — Z (S) $4310

1910.95 I02 II B

Other-than-serious 1 instance 75 exposed
Issued
Feb 6, 2017
Abate by
Mar 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.95(i)(2)(ii)(B): The employer did not ensure that hearing protectors are worn by any employee who is exposed to an 8-hour time-weighted average of 85 decibels or greater and has experienced a standard threshold shift:     a) Anaconda Foundry Fabrication Company, Inc.:  On November 29, 2016, and at times prior, employees were exposed to standard threshold shifts while welding, cutting, grinding, and fabricating without adequate hearing protection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV B

Other-than-serious 1 instance 5 exposed
Issued
Feb 6, 2017
Abate by
Mar 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors:   a) The East Fab Shop:  On November 1, 2016 and at times prior, employees are exposed to shock hazards while using equipment attached to flexible cord that was observed running through holes in the wall.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Anaconda Foundry Fabrication Company, INC.'s full OSHA safety record →