Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SHIRIN K. MIRZAYEV

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SHIRIN K. MIRZAYEV in 818-824 STATE STREET, ERIE, PA 16501 (NAICS 238160). OSHA activity number 341896363.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Shirin K. Mirzayev — free Get an email when a new federal OSHA severe-injury report for Shirin K. Mirzayev is published. One employer, no account, unsubscribe in one click.
Establishment
SHIRIN K. MIRZAYEV
Site address
818-824 STATE STREET
City
ERIE
State
PA
ZIP
16501
Mailing
3209 WEST 23RD STREET, ERIE, PA 16506
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

7 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 4 exposed
Issued
May 4, 2017
Abate by
May 25, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:  A.) Shirin K. Mirzayev dba Super-Roofer, 818-824 State Street, Erie, PA  16501, roof of the structure, on or about November 7, 2016 and times prior thereto:  Employees were performing roofing activities including, but not limited to, screwing roofing fasteners down for the roofing operation.  Employees were not utilizing a means or method of fall protection on the east side of the roof as they were exposed to a fall hazard of greater than 25-feet.
Recent events (1)
  • — Z (S) $3803

1926.502 F01

Serious Gravity 10 1 instance 4 exposed
Issued
May 4, 2017
Abate by
May 25, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(1): Warning lines were not erected around all sides of the roof work area:  A.) Shirin K. Mirzayev dba Super-Roofer, 818-824 State Street, Erie, PA  16501, roof of the structure, on or about November 7, 2016 and times prior thereto:  Employees were conducting roofing work.  Employees were utilizing a warning line system that did not encompass the entire perimeter of the roof.  The warning system was not present on the roof at the northeast corner of the structure where the work was taking place.
Recent events (1)
  • — Z (S) $0

1926.502 F01 I

Serious Gravity 10 1 instance 4 exposed
Issued
May 4, 2017
Abate by
May 25, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(1)(i): When no mechanical equipment was being used the warning line was not erected at least 6 feet (1.8m) from the roof edge:  A.) Shirin K. Mirzayev dba Super-Roofer, 818-824 State Street, Erie, PA  16501, roof of the structure, on or about November 7, 2016 and times prior thereto:  Employees were conducting roofing work.  The warning line on the north side of the roof was between 49-inches and 63-inches from the roof edge.
Recent events (1)
  • — Z (S) $0

1926.501 B04 I

Serious Gravity 10 1 instance 4 exposed
Issued
May 4, 2017
Abate by
May 25, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes:  A.) Shirin K. Mirzayev dba Super-Roofer, 818-824 State Street, Erie, PA  16501, roof of the structure, on or about November 7, 2016 and times prior thereto:  Employees were walking/working on the roof of the structure within three feet of two skylights.  Employees were not utilizing a means or method of fall protection when walking/working near the skylights, nor were the skylights protected with covers or a guardrail system.  Employees were exposed to a 15-foot fall hazard.
Recent events (1)
  • — Z (S) $3803

1926.501 B01

Serious Gravity 10 1 instance 4 exposed
Issued
May 4, 2017
Abate by
May 25, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  A.) Shirin K. Mirzayev dba Super-Roofer, 818-824 State Street, Erie, PA  16501, roof of the structure, on or about November 7, 2016 and times prior thereto:  Employees were walking across an elevated walkway from a stairwell area to the roof area where roofing activities were being conducted.  Employees were not utilizing a means or method of fall protection including, but not limited to, guardrail systems, safety net systems, or personal fall arrest systems, when walking across the walkway.  Employees were exposed to a 14.2 to 17.1-foot fall hazard to the roofs below.
Recent events (1)
  • — Z (S) $3803

1926.1051 A

Serious Gravity 10 1 instance 4 exposed
Issued
May 4, 2017
Abate by
May 25, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided:  A.) Shirin K. Mirzayev dba Super-Roofer, 818-824 State Street, Erie, PA  16501, roof of the structure, on or about November 7, 2016 and times prior thereto:  Employees were walking across an elevated walkway from a stairwell area to the roof area where roofing activities were being conducted.  The break in elevation between the elevated walkway and the roof where the work was being conducted was 3.4-feet.  Employees were climbing between to elevated walkway and roof without the use of a stairway or ladder.
Recent events (1)
  • — Z (S) $0

1926.152 D02

Other-than-serious 1 instance 4 exposed
Issued
May 4, 2017
Abate by
May 25, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.152(d)(2): A portable fire extinguisher having a rating of not less than 20-B units was not located between 25 feet and 75 feet from flammable liquid storage area(s) located outside:  A.) Shirin K. Mirzayev dba Super-Roofer, 818-824 State Street, Erie, PA  16501, roof of the structure, on or about November 7, 2016 and times prior thereto:  Flammable materials including, but not limited to, Low-VOC Bonding Adhesive was stored on the roof of the structure for roofing activities.  The closest fire extinguisher to the storage area was 162-feet away.
Recent events (1)
  • — Z (O) $0

View Shirin K. Mirzayev's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341896363.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.