ERIE, PA —
OSHA Inspection: SHIRIN K. MIRZAYEV
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SHIRIN K. MIRZAYEV in 818-824 STATE STREET, ERIE, PA 16501 (NAICS 238160). OSHA activity number 341896363.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SHIRIN K. MIRZAYEV
- Site address
- 818-824 STATE STREET
- City
- ERIE
- State
- PA
- ZIP
- 16501
- Mailing
- 3209 WEST 23RD STREET, ERIE, PA 16506
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.501 B10
- Issued
- May 4, 2017
- Abate by
- May 25, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: A.) Shirin K. Mirzayev dba Super-Roofer, 818-824 State Street, Erie, PA 16501, roof of the structure, on or about November 7, 2016 and times prior thereto: Employees were performing roofing activities including, but not limited to, screwing roofing fasteners down for the roofing operation. Employees were not utilizing a means or method of fall protection on the east side of the roof as they were exposed to a fall hazard of greater than 25-feet.
Recent events (1)
- — Z (S) $3803
1926.502 F01
- Issued
- May 4, 2017
- Abate by
- May 25, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(f)(1): Warning lines were not erected around all sides of the roof work area: A.) Shirin K. Mirzayev dba Super-Roofer, 818-824 State Street, Erie, PA 16501, roof of the structure, on or about November 7, 2016 and times prior thereto: Employees were conducting roofing work. Employees were utilizing a warning line system that did not encompass the entire perimeter of the roof. The warning system was not present on the roof at the northeast corner of the structure where the work was taking place.
Recent events (1)
- — Z (S) $0
1926.502 F01 I
- Issued
- May 4, 2017
- Abate by
- May 25, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(f)(1)(i): When no mechanical equipment was being used the warning line was not erected at least 6 feet (1.8m) from the roof edge: A.) Shirin K. Mirzayev dba Super-Roofer, 818-824 State Street, Erie, PA 16501, roof of the structure, on or about November 7, 2016 and times prior thereto: Employees were conducting roofing work. The warning line on the north side of the roof was between 49-inches and 63-inches from the roof edge.
Recent events (1)
- — Z (S) $0
1926.501 B04 I
- Issued
- May 4, 2017
- Abate by
- May 25, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes: A.) Shirin K. Mirzayev dba Super-Roofer, 818-824 State Street, Erie, PA 16501, roof of the structure, on or about November 7, 2016 and times prior thereto: Employees were walking/working on the roof of the structure within three feet of two skylights. Employees were not utilizing a means or method of fall protection when walking/working near the skylights, nor were the skylights protected with covers or a guardrail system. Employees were exposed to a 15-foot fall hazard.
Recent events (1)
- — Z (S) $3803
1926.501 B01
- Issued
- May 4, 2017
- Abate by
- May 25, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: A.) Shirin K. Mirzayev dba Super-Roofer, 818-824 State Street, Erie, PA 16501, roof of the structure, on or about November 7, 2016 and times prior thereto: Employees were walking across an elevated walkway from a stairwell area to the roof area where roofing activities were being conducted. Employees were not utilizing a means or method of fall protection including, but not limited to, guardrail systems, safety net systems, or personal fall arrest systems, when walking across the walkway. Employees were exposed to a 14.2 to 17.1-foot fall hazard to the roofs below.
Recent events (1)
- — Z (S) $3803
1926.1051 A
- Issued
- May 4, 2017
- Abate by
- May 25, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: A.) Shirin K. Mirzayev dba Super-Roofer, 818-824 State Street, Erie, PA 16501, roof of the structure, on or about November 7, 2016 and times prior thereto: Employees were walking across an elevated walkway from a stairwell area to the roof area where roofing activities were being conducted. The break in elevation between the elevated walkway and the roof where the work was being conducted was 3.4-feet. Employees were climbing between to elevated walkway and roof without the use of a stairway or ladder.
Recent events (1)
- — Z (S) $0
1926.152 D02
- Issued
- May 4, 2017
- Abate by
- May 25, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.152(d)(2): A portable fire extinguisher having a rating of not less than 20-B units was not located between 25 feet and 75 feet from flammable liquid storage area(s) located outside: A.) Shirin K. Mirzayev dba Super-Roofer, 818-824 State Street, Erie, PA 16501, roof of the structure, on or about November 7, 2016 and times prior thereto: Flammable materials including, but not limited to, Low-VOC Bonding Adhesive was stored on the roof of the structure for roofing activities. The closest fire extinguisher to the storage area was 162-feet away.
Recent events (1)
- — Z (O) $0
More inspections at Shirin K. Mirzayev
View Shirin K. Mirzayev's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341896363.