Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OMEGA LOGGING, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of OMEGA LOGGING, INC. in 21 COUNCIL STREET, WHEATLAND, PA 16161 (NAICS 321113). OSHA activity number 341902211.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Omega Logging, INC. — free Get an email when a new federal OSHA severe-injury report for Omega Logging, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
OMEGA LOGGING, INC.
Site address
21 COUNCIL STREET
City
WHEATLAND
State
PA
ZIP
16161
Mailing
P.O. BOX 336, WHEATLAND, PA 16161
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
11
Ownership type
A

10 citations on file for this inspection.

1910.157 G01

Serious Gravity 1 1 instance 3 exposed
Issued
May 5, 2017
Abate by
Jul 10, 2017
Penalty
Initial $2,173 · Current $1,900 Reduced
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:    A.)  Omega Logging, Inc., 21 Council Street, Wheatland, PA 16161, on or about November 9, 2016 and times prior thereto:  Employees are provided with and permitted to use portable dry chemical fire extinguishers.  Employees have not had portable fire extinguisher training.
Recent events (2)
  • — I (S) $1900
  • — Z (S) $2173

1910.253 B04 III

Serious Gravity 1 1 instance 3 exposed
Issued
May 5, 2017
Penalty
Initial $1,847 · Current $1,800 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    A.)  Omega Logging, Inc., 21 Council Street, Wheatland, PA 16161, shop area, on or about November 9, 2016 and times prior thereto:  Three oxygen and one acetylene cylinder were stored within less than one foot of each other.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $1847

1910.101 B

Serious Gravity 1 1 instance 3 exposed
Issued
May 5, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): 29 CFR 1910.101(b):  Section 3.4.4, Compressed Gas Association Pamphlet P11965, as adopted by 29 CFR 1910.101(b): Compressed gas cylinder(s) not in use were not properly supported to prevent them from being knocked over:  A.)  Omega Logging, Inc., 21 Council Street, Wheatland, PA 16161, shop area, on or about November 9, 2016 and times prior thereto:  Cylinders containing gases including, but not limited to, oxygen and acetylene, were freestanding and were not secured from tipping over.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.265 C20 I

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
May 5, 2017
Abate by
Jun 1, 2017
Penalty
Initial $2,897 · Current $0 Reduced
29 CFR 1910.265(c)(20)(i): Blower collecting, and exhaust systems were not designed, constructed, and maintained in accordance with American National Standards Z33.1-1961 (For the Installation of Blower and Exhaust Systems for Dust, Stock, and Vapor Removal or Conveying) and Z12.20-1962 (R1969) (Code for the Prevention of Dust Explosion in Woodworking and Wood Flour Manufacturing Plants), which are incorporated by reference as specified in Sec. 1910.6:    Section 231, American National Standards Z33.1-1961, as adopted by 29 CFR 1910.265(c)(20)(i):  Ducts shall be constructed entirely of sheet metal or other noncombustible material, and of adequate strength and rigidity to meet the conditions of service and installation requirements, and shall be properly protected where subject to mechanical injury.  Section 1235, American National Standards Z12.20-1962, as adopted by 29 CFR 1910.265(c)(20)(i):  Exhaust piping shall be of proper gage galvanized sheet steel or black sheet steel protected against corrosion, or of other noncombustible materials of equal strength, corrosion and abrasion resisting properties.  A.)  Omega Logging, Inc., 21 Council Street, Wheatland, PA 16161, on or about November 9, 2016 and times prior thereto:  PVC Plastic piping was used to convey sawdust from machinery including, but not limited to, a Cornell Gang Resaw, a Smith Band Resaw and the head saws.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2897

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
May 5, 2017
Abate by
Jun 1, 2017
Penalty
Initial $2,897 · Current $2,000 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    A.)  Omega Logging, Inc., 21 Council Street, Wheatland, PA 16161, resaw room, on or about November 9, 2016 and times prior thereto:  A power transmission belt and pulley on the red Smith Band Resaw that transmitted power to a conveyer was within 5-feet of the floor and was not completely guarded.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2897

1910.265 E03 II A

Serious Gravity 5 1 instance 1 exposed
Issued
May 5, 2017
Abate by
Jun 1, 2017
Penalty
Initial $3,622 · Current $1,800 Reduced
29 CFR 1910.265(e)(3)(ii)(a): Banks of circular gang resaws were not guarded by a hood:    A.)  Omega Logging, Inc., 21 Council Street, Wheatland, PA 16161, resaw room, on or about November 9, 2016 and times prior thereto:  The Cornell Gang Resaw had a guard opening of 20-inches wide by 14-inches in height.  The guard was not adequate as it allowed access into the point of operation.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3622

1910.265 E03 II B

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
May 5, 2017
Abate by
Jun 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.265(e)(3)(ii)(b): Circular gang resaws were not provided with safety fingers or other antikickback devices:  A.)  Omega Logging, Inc., 21 Council Street, Wheatland, PA 16161, resaw room, on or about November 9, 2016 and times prior thereto:  The Cornell Gang Resaw had a guard opening of 20-inches wide by 14-inches in height.  The anti-kickback device that was used only cover half of the opening and was not effective in preventing kickback of wood fragments.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.265 E03 II E

Serious Gravity 5 1 instance 1 exposed
Issued
May 5, 2017
Abate by
Jun 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.265(e)(3)(ii)(e): Feed rolls were not guarded.  A.)  Omega Logging, Inc., 21 Council Street, Wheatland, PA 16161, resaw room, on or about November 9, 2016 and times prior thereto:  The Cornell Gang Resaw had a guard opening of 20-inches wide by 14-inches in height.  The guard opening allowed for access of employees fingers and hands into the moving feed rollers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Other-than-serious 1 instance 1 exposed
Issued
May 5, 2017
Abate by
Aug 10, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    A.)  Omega Logging, Inc., 21 Council Street, Wheatland, PA 16161, on or about November 9, 2016 and times prior thereto:  Employees perform service and maintenance on equipment including, but not limited to, the Cornell Resaw.  Periodic inspections have not been conducted with authorized employees.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 3 exposed
Issued
May 5, 2017
Abate by
Jun 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  A.)  Omega Logging, Inc., 21 Council Street, Wheatland, PA 16161, shop area, on or about November 9, 2016 and times prior thereto:  Items including, but not limited to, a wheel borrow and a pedestal grinder were stored within one to three feet of electrical panels including, but not limited to, disconnect panel #7.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0