SHERIDAN, OR —
OSHA Inspection: FEDERAL BUREAU OF PRISONS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FEDERAL BUREAU OF PRISONS in 27072 BALLSTON ROAD, SHERIDAN, OR 97378 (NAICS 922140). OSHA activity number 341906410.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FEDERAL BUREAU OF PRISONS
- Site address
- 27072 BALLSTON ROAD
- City
- SHERIDAN
- State
- OR
- ZIP
- 97378
- Mailing
- P.O. BOX 5001, SHERIDAN, OR 97378
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 922140
- Employees
- 300
- Ownership type
- D
Citations
6 citations on file for this inspection.
1910.23 A08 II
- Issued
- Feb 24, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(a)(8)(ii): A floor hole cover of standard strength and construction. While the cover is not in place, the floor hole shall be constantly attended by someone or shall be protected by a removable standard railing. (a) FCI, Kitchen, on or about November 8, 2016, and at times prior thereto, where a floor drain (approximately 9 inches x 9 inches x 4 inches deep) did not have a cover to prevent employees from a slip, trip, and/or fall hazard. Note: Abatement was completed at time of inspection.
Recent events (1)
- — Z (S) $0
1910.151 C
- Issued
- Feb 24, 2017
- Abate by
- Mar 22, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) Garage, Bus Bay, on or about November 8, 2016, and at times prior thereto, where employees transferred corrosive vehicle cleaning chemicals. Note: Abatement certification is required for this item.
Recent events (1)
- — Z (S) $0
1910.242 B
- Issued
- Feb 24, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) Garage, Bus Bay, on or about November 8, 2016, and at times prior thereto, compressed air nozzle was not designed to reduced compressed air pressure. Note: Abatement was completed at the time of the inspection.
Recent events (1)
- — Z (S) $0
1910.307 C02 I
- Issued
- Feb 24, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(c)(2)(i): Equipment in hazardous (classified) location(s) was not approved for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that was or could be present: (a) Wood Shop, dust collection system, on or about November 8, 2016, and at times prior thereto, electrical junction box was not rated for Class II Division I where combustible dusts were being collected. (b) Wood Shop, dust collection system, on or about November 8, 2016, and at times prior thereto, electrical knife switch was not rated for Class II Division I where combustible wood dusts were being collected. Note: Abatement was completed at the time of the inspection
Recent events (1)
- — Z (S) $0
1910.1200 G08
- Issued
- Feb 24, 2017
- Abate by
- Mar 22, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace: (a) On or about November 8, 2016, and at times prior thereto, not all Safety Data Sheets contained complete up to date information. An example includes, but is not limited to, Health Services, Spartan Chemical data sheet from 2006 that did not contain pictograms and other required data. Note: Abatement certification is required for this item.
Recent events (1)
- — Z (S) $0
1910.134 D01 III
- Issued
- Feb 24, 2017
- Abate by
- Mar 22, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: (a) Powerhouse, on or about November 8, 2016, and at times prior thereto, an identification of the boiler soot was not conducted to determine the respiratory hazards and adequacy of the respiratory protection prior to employees conducting the annual cleaning of the boilers. Note: Abatement certification is required for this item.
Recent events (1)
- — Z (O) $0
More inspections at Federal Bureau of Prisons
View Federal Bureau of Prisons's full OSHA safety record →
More inspections in this industry (NAICS 922140)
More inspections in OR