TAVARES, FL —
OSHA Inspection: METRO STEEL & PIPE SUPPLY, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of METRO STEEL & PIPE SUPPLY, INC. in 470 COUNTY ROAD 448, TAVARES, FL 32778 (NAICS 331110). OSHA activity number 341918761.
Where did this inspection happen?
- Establishment
- METRO STEEL & PIPE SUPPLY, INC.
- Site address
- 470 COUNTY ROAD 448
- City
- TAVARES
- State
- FL
- ZIP
- 32778
- Mailing
- 470 COUNTY ROAD 448, TAVARES, FL 32778
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331110
- Employees
- 50
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.132 A
- Issued
- Feb 22, 2017
- Abate by
- Mar 20, 2017
- Penalty
- Initial $3,802 · Current $1,901 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: (a) Welding Area - Arm sleeves were not used during welding operations to protect against sparks and UV light, on or about November 30, 2016.
Recent events (2)
- — I (S) $1901
- — Z (S) $3802
1910.132 D01
- Issued
- Feb 22, 2017
- Abate by
- Mar 20, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): (a) Welding Area - No hazard assessment was completed for exposed arms and sleeves were not used during welding operations to protect against sparks and UV light, on or about November 30, 2016.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Feb 22, 2017
- Abate by
- Mar 29, 2017
- Penalty
- Initial $5,070 · Current $2,535 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Welding Area - No program was developed and welders were exposed to iron oxide fume, antimony fume, copper fume and manganese fume, on or about November 30, 2016.
Recent events (2)
- — I (S) $2535
- — Z (S) $5070
1910.1200 H01
- Issued
- Feb 22, 2017
- Abate by
- Mar 29, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Welding Area - No training on the hazards of iron oxide fume, antimony fume, copper fume and manganese fume was provided to welders, on or about November 30, 2016.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C02 II
- Issued
- Feb 22, 2017
- Abate by
- Mar 29, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) Welding Area - A welder was voluntarily wearing a tight-fitting respirator and no program was established, on or about November 30, 2016. b) Welding Area - A welder was voluntarily wearing a tight-fitting respirator and no medical evaluation was provided, on or about November 30, 2016.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 K06
- Issued
- Feb 22, 2017
- Abate by
- Mar 29, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:(a) (LOCATION) (IDENTIFY SPECIFIC OPERATION/CONDITION) (DESCRIBE HAZARD) a) Welding Area - A welder was voluntarily wearing a tight-fitting respirator and had not been provided Appendix D, on or about November 30, 2016.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Metro Steel & Pipe Supply, INC.
View Metro Steel & Pipe Supply, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331110)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341918761.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.