Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CARDWELL LUMBER INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CARDWELL LUMBER INC. in HIGHWAY 15 NORTH 2 MILES, NOVELTY, MO 63460 (NAICS 321113). OSHA activity number 341924090.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cardwell Lumber INC. — free Get an email when a new federal OSHA severe-injury report for Cardwell Lumber INC. is published. One employer, no account, unsubscribe in one click.
Site address
HIGHWAY 15 NORTH 2 MILES
City
NOVELTY
State
MO
ZIP
63460
Mailing
P.O. BOX 117, NOVELTY, MO 63460
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
120
Ownership type
A

8 citations on file for this inspection.

1910.106 E02 II

Other-than-serious 3 instances 10 exposed
Issued
Dec 14, 2016
Abate by
Feb 2, 2017
Penalty
Initial $8,820 · Current $2,500 Reduced
29 CFR 1910.106(e)(2)(ii):  Flammable liquids were not stored in tanks or closed containers:    a/  Inside of the Saw Mill, three, plastic containers partially filled with stored gasoline were not closed.
Recent events (2)
  • — I (O) $2500
  • — Z (S) $8820

1910.157 C01

Other-than-serious 2 instances 10 exposed
Issued
Dec 14, 2016
Abate by
Feb 2, 2017
Penalty
Initial $8,820 · Current $2,500 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    a/  Inside of the Header Department, two portable fire extinguishers were partially blocked.  One fire extinguisher was partially blocked by stacked lumber.  The second fire extinguisher was partially blocked by a conveyor system.
Recent events (2)
  • — I (O) $2500
  • — Z (S) $8820

1910.157 E02

Other-than-serious 5 instances 10 exposed
Issued
Dec 14, 2016
Abate by
Feb 2, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:    a/  Inside of the Header Department, the mounted, portable fire extinguishers were not inspected monthly.  The lack of tags or legible tags made it difficult to determine when the last monthly inspection had been performed.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 G01 I

Other-than-serious 1 instance 2 exposed
Issued
Dec 14, 2016
Abate by
Feb 2, 2017
Penalty
Initial $8,820 · Current $2,500 Reduced
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less:    a/  Inside of the Maintenance Shop, the working space in front of a 220 volt circuit breaker panel box was partially blocked by a fixed air compressor, two 55-gallon drums, hoses, and an open drum of motor oil.
Recent events (2)
  • — I (O) $2500
  • — Z (S) $8820

1910.305 B01 I

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 14, 2016
Abate by
Feb 2, 2017
Penalty
Initial $8,820 · Current $5,250 Reduced
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:    a/  Inside of the Maintenance Shop, a total of six insulated wires entered through two openings leading to a variable speed motor belonging to a JET Drill Press, unknown m/n or s/n.  These conductors were not protected from abrasions.
Recent events (2)
  • — I (S) $5250
  • — Z (S) $8820

1910.335 A01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 14, 2016
Abate by
Feb 2, 2017
Penalty
Initial $8,820 · Current $5,250 Reduced
29 CFR 1910.335(a)(1)(i):  Employees working in areas where there are potential electrical hazards were not provided with, and did not use, electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed:    a/  Employee(s) performing lockout/tagout on circuit breaker panel boxes or the equivalent were not provided with suitable protective equipment to protect against arc flash.  Such equipment would include, at a minimum, a Class E Hard Hat, tinted face shield, a rated arc flash suit with a suitable calorie rating, and electrical gloves.
Recent events (2)
  • — I (S) $5250
  • — Z (S) $8820

1910.147 C01

Other-than-serious 1 instance 50 exposed
Issued
Dec 14, 2016
Abate by
Feb 2, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(1):  The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment would be isolated from the energy source and rendered inoperative:  a/  A lockout/tagout program did not exist in writing.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 J01

Other-than-serious 1 instance 120 exposed
Issued
Dec 14, 2016
Abate by
Feb 2, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(j)(1): Employers did train employees regarding the new label elements and safety data sheets format by December 1, 2013:  a/  As of 11/22/16, employees were not instructed in the meaning of pictograms or the new safety data sheet format.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Cardwell Lumber INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341924090.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.