Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAGGIE CHACON

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MAGGIE CHACON in 13351MONTANA AVE, EL PASO, TX 79938 (NAICS 238120). OSHA activity number 341925303.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Maggie Chacon — free Get an email when a new federal OSHA severe-injury report for Maggie Chacon is published. One employer, no account, unsubscribe in one click.
Establishment
MAGGIE CHACON
Site address
13351MONTANA AVE
City
EL PASO
State
TX
ZIP
79938
Mailing
13351MONTANA AVE, EL PASO, TX 79938
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
22
Ownership type
A

10 citations on file for this inspection.

1910.22 A03

Serious Gravity 1 1 instance 4 exposed
Issued
May 11, 2017
Abate by
Jun 1, 2017
Penalty
Initial $2,173 · Current $1,600 Reduced
29 CFR 1910.22(a)(3): Every floor, working place, and passageway was not kept free from protruding objects, loose boards, corrosion, leaks, spills, snow, and ice.    Machine Shop:  On or about November 21, 2016 there was a spill of a mixture of motor oil and engine coolant on the entrance of the shop floor.  This condition exposed employees to a slip hazard.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $2173

1910.212 A03 II

Serious Gravity 5 3 instances 3 exposed
Issued
May 11, 2017
Abate by
Jul 14, 2017
Penalty
Initial $4,346 · Current $3,000 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    On or about November 21, 2016 points of operation of machinery were not guarded to prevent employees from having any part of their body in the danger zone during operating cycles.  This condition exposed employees to a struck-by hazard in the following instances:    A) Cyclone Hem Saw    B) H160XLM Hem Saw    C) Piranha Ironworker Press Brake
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4346

1910.243 C03

Serious Gravity 5 2 instances 2 exposed
Issued
May 11, 2017
Abate by
Jun 1, 2017
Penalty
Initial $4,346 · Current $3,000 Reduced
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel:    Machine Shop: On or about November 21, 2016 a portable Dewalt Angle Grinder did not have safety guard located between the operator and wheel: This condition exposed employees to a struck-by hazard.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4346

1910.303 B01 IV

Serious Gravity 5 3 instances 2 exposed
Issued
May 11, 2017
Abate by
Jun 1, 2017
Penalty
Initial $4,346 · Current $3,000 Reduced
29 CFR 1910.303(b)(1)(iv): Electric equipment was not free from recognized hazards that were likely to cause serious physical harm to employees, such as damaged electrical insulation:      Machine Shop: On or about November 21, 2016 extension cord had damaged electrical insulation, this condition exposed employees to an electrical shock hazard. For the following instances.    A) Extension cord powering stereo    B) Rebar Cutting Machine    C) Icaro Bending Machine
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4346

1910.304 G05

Serious Gravity 5 2 instances 3 exposed
Issued
May 11, 2017
Abate by
Jun 1, 2017
Penalty
Initial $4,346 · Current $3,000 Reduced
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.    Machine Shop:  On or about November 21, 2016 path to ground from equipment was not continuous and effective.  This condition exposed employees to an electrical shock hazard in the following instances:    A) MasterCool Air Conditioner     B) Dewalt Bench Grinder
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4346

1910.305 B01 I

Serious Gravity 5 2 instances 2 exposed
Issued
May 11, 2017
Abate by
Jun 1, 2017
Penalty
Initial $4,346 · Current $3,000 Reduced
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:    Machine Shop: On or about November 21, 2016 fittings were not protected from abrasions and wires were exposed.  This condition exposed employees to an electrical shock hazard.    A) GE Breaker Switch    B) Rebar Cutting Machine
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4346

1910.305 B02 I

Serious Gravity 5 1 instance 3 exposed
Issued
May 11, 2017
Abate by
Jun 1, 2017
Penalty
Initial $4,346 · Current $3,000 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    Outside Machine Shop: On or about November 21, 2016 an outdoor receptacle did not have a faceplate.  This condition exposed employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4346

1910.305 J01 I

Serious Gravity 5 1 instance 3 exposed
Issued
May 11, 2017
Abate by
Jun 1, 2017
Penalty
Initial $4,346 · Current $0 Reduced
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located had live parts normally exposed to employee contact:    Outside of Machine Shop: On or about November 21, 2016 an outdoor receptacle was damaged and had live parts exposed to employee contact.  This condition exposed employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4346

1910.305 J02 V

Serious Gravity 5 1 instance 3 exposed
Issued
May 11, 2017
Abate by
Jun 1, 2017
Penalty
Initial $4,346 · Current $0 Reduced
29 CFR 1910.305(j)(2)(v): A receptacle installed outdoors in a location protected from the weather or in other damp locations did not have an enclosure for the receptacle that was weatherproof when the receptacle was covered:    Outside of Machine Shop: On or about November 21, 2016 an outdoor receptacle did not have a weatherproof cover. This condition exposed employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4346

1910.134 H02 I

Other-than-serious 1 instance 1 exposed
Issued
May 11, 2017
Abate by
Jun 1, 2017
Penalty
Initial $406 · Current $400 Reduced
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:    Machine Shop: On or about November 21, 2016 a half-face respirator was not stored to protect from damage.  This condition exposed employees to a health hazard.
Recent events (2)
  • — I (O) $400
  • — Z (O) $406

View Maggie Chacon's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341925303.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.