ZION, IL —
OSHA Inspection: FEDERAL EQUIPMENT & SERVICES, INCORPORATED
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of FEDERAL EQUIPMENT & SERVICES, INCORPORATED in 3200 16TH STREET, ZION, IL 60099 (NAICS 332116). OSHA activity number 341934198.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FEDERAL EQUIPMENT & SERVICES, INCORPORATED
- Site address
- 3200 16TH STREET
- City
- ZION
- State
- IL
- ZIP
- 60099
- Mailing
- 3200 16TH STREET, ZION, IL 60099
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332116
- Employees
- 9
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C01
- Issued
- Jan 23, 2017
- Abate by
- Feb 16, 2017
- Penalty
- Initial $5,976 · Current $5,976
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On or about November 2, 2016, Federal Equipment & Services, Incorporated did not establish a program consisting of an energy control procedure, employee training, and periodic inspections, to protect employees from unexpected energizing, start up or release of stored energy during service, maintenance, set-up and/or die changes, and inspections of the mechanical power presses. Federal Equipment & Services, Incorporated was previously cited for a violation of this Occupational Safety and Health Standard, 29 CFR 1910.147(c)(1), which was contained in OSHA inspection number 1078444, citation number 1, item number 1a and was affirmed as a final order on February 5, 2016, with respect to a workplace located at 3200 16th Street, Zion, Illinois 60099. In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (3)
- — A (R) $5976
- — I (R) $3600
- — Z (R) $5976
1910.147 C04 I
- Issued
- Jan 23, 2017
- Abate by
- Mar 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about November 2, 2016, Federal Equipment & Services, Incorporated did not develop, document and utilize a procedure to control potentially hazardous energy when an employee performed set ups and inspections of mechanical power presses. Federal Equipment & Services, Incorporated was previously cited for a violation of this Occupational Safety and Health Standard, 29 CFR 1910.147(c)(4)(i), which was contained in OSHA inspection number 1078444, citation number 1, item number 1b and was affirmed as a final order on February 5, 2016, with respect to a workplace located at 3200 16th Street, Zion, Illinois 60099. In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (3)
- — A (R) $0
- — I (R) $0
- — Z (R) $0
1910.217 D09 IV
- Issued
- Jan 23, 2017
- Abate by
- Feb 16, 2017
- Penalty
- Initial $5,976 · Current $5,976
General-duty citation text
29 CFR 1910.217(d)(9)(iv): Safety blocks were not used when mechanical power press die(s) were being adjusted or repaired in the press. a) On or about November 2, 2016, Federal Equipment & Services, Incorporated did not ensure safety blocks were used when the die was being adjusted in press #19. Federal Equipment & Services, Incorporated was previously cited for a violation of this Occupational Safety and Health Standard, 29 CFR 1910.217(d)(9)(iv), which was contained in OSHA inspection number 1078444, citation number 1, item number 3b and was affirmed as a final order on February 5, 2016, with respect to a workplace located at 3200 16th Street, Zion, Illinois 60099. In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (3)
- — A (R) $5976
- — I (R) $3600
- — Z (R) $5976
1910.217 E01 I
- Issued
- Jan 23, 2017
- Abate by
- Feb 16, 2017
- Penalty
- Initial $5,976 · Current $5,976
General-duty citation text
29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: a) On October 28, 2016, Federal Equipment & Services, Incorporated did not establish a formal, documented program of periodic inspections for the mechanical power presses to ensure the safe operation and reliability of the mechanical power presses. Federal Equipment & Services, Incorporated was previously cited for a violation of this Occupational Safety and Health Standard, 29 CFR 1910.217(e)(1)(i), which was contained in OSHA inspection number 1078444, citation number 1, item number 4a and was affirmed as a final order on February 5, 2016, with respect to a workplace located at 3200 16th Street, Zion, Illinois 60099. In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (3)
- — A (R) $5976
- — I (R) $3600
- — Z (R) $5976
More inspections at Federal Equipment & Services, Incorporated
View Federal Equipment & Services, Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 332116)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341934198.