SCOTT DEPOT, WV —
OSHA Inspection: ANDRITZ SEPARATION, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ANDRITZ SEPARATION, INC. in 123 ERSKINE LANE, SCOTT DEPOT, WV 25560 (NAICS 332710). OSHA activity number 341936904.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANDRITZ SEPARATION, INC.
- Site address
- 123 ERSKINE LANE
- City
- SCOTT DEPOT
- State
- WV
- ZIP
- 25560
- Mailing
- 123 ERSKINE LANE, SCOTT DEPOT, WV 25560
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 34
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jan 19, 2017
- Abate by
- Feb 14, 2017
- Penalty
- Initial $7,243 · Current $5,432 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Gear Unit Assembly: On or about November 22, 2016 energy isolation procedures had not been developed to secure a D6LL Centrifuge gear box from falling while an employee worked on it in that the employee was working on the load while is was suspended from a hoist.
Recent events (2)
- — I (S) $5432.25
- — Z (S) $7243
1910.184 C09
- Issued
- Jan 19, 2017
- Abate by
- Feb 14, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(c)(9): Employee(s) were not kept clear of load(s) suspended, or about to be lifted by sling(s) (a) Gear Unit Assembly: On or about November 22, 2016 an employee was not keeping clear of a suspended load in that he was installing bolts on a suspended centrifuge gear box weighing approximately 700 pounds.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Jan 19, 2017
- Abate by
- Feb 14, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) On or about November 29, 2016 the employer had not conducted periodic inspections at least annually of the energy control procedure.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Andritz Separation, INC.
View Andritz Separation, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341936904.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.