Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ANDRITZ SEPARATION, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ANDRITZ SEPARATION, INC. in 123 ERSKINE LANE, SCOTT DEPOT, WV 25560 (NAICS 332710). OSHA activity number 341936904.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Andritz Separation, INC. — free Get an email when a new federal OSHA severe-injury report for Andritz Separation, INC. is published. One employer, no account, unsubscribe in one click.
Site address
123 ERSKINE LANE
City
SCOTT DEPOT
State
WV
ZIP
25560
Mailing
123 ERSKINE LANE, SCOTT DEPOT, WV 25560
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
34
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 19, 2017
Abate by
Feb 14, 2017
Penalty
Initial $7,243 · Current $5,432 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a)  Gear Unit Assembly:  On or about November 22, 2016 energy isolation procedures had not been developed to secure a D6LL Centrifuge gear box from falling while an employee worked on it in that the employee was working on the load while is was suspended from a hoist.
Recent events (2)
  • — I (S) $5432.25
  • — Z (S) $7243

1910.184 C09

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 19, 2017
Abate by
Feb 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.184(c)(9): Employee(s) were not kept clear of load(s) suspended, or about to be lifted by sling(s)  (a)  Gear Unit Assembly:  On or about November 22, 2016 an employee was not keeping clear of a suspended load in that he was installing bolts on a suspended centrifuge gear box weighing approximately 700 pounds.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Other-than-serious 1 instance 1 exposed
Issued
Jan 19, 2017
Abate by
Feb 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a)  On or about November 29, 2016 the employer had not conducted periodic inspections at least annually of the energy control procedure.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Andritz Separation, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341936904.