SAIPAN, MP —
OSHA Inspection: CWM TRUST, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CWM TRUST, LLC. in #6 GUALO RAI PLAZA, CHALAN PALE ARNOLD ROAD, SAIPAN, MP 96950 (NAICS 236220). OSHA activity number 341957371.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CWM TRUST, LLC.
- Site address
- #6 GUALO RAI PLAZA, CHALAN PALE ARNOLD ROAD
- City
- SAIPAN
- State
- MP
- ZIP
- 96950
- Mailing
- P.O. BOX 500087 CK, SAIPAN, MP 96950
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 12
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.100 A
- Issued
- Jan 10, 2017
- Penalty
- Initial $1,817 · Current $1,272 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On December 6, 2016, employees were working underneath other employees and head protection was not worn, exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $1271.9
- — Z (S) $1817
1926.403 B02
- Issued
- Jan 10, 2017
- Penalty
- Initial $2,138 · Current $1,497 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) On December 6, 2016, two metal gang boxes designed to be installed and mounted in a wall, were lying on the floor and mounted to a block of wood, exposing employees to electrical and fire hazards.
Recent events (2)
- — I (S) $1496.6
- — Z (S) $2138
1926.404 B01 I
- Issued
- Jan 10, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) On December 6, 2016, at the temporary power source area, ground fault circuit interrupters or an assured equipment grounding conductor program was not used, exposing employees to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 G02 IV
- Issued
- Jan 10, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) On December 6, 2016, a temporary metal gang box did not have a strain relief device causing a transmission of tension to joints and/or terminals, exposing employees to electrical and fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.403 I02 I
- Issued
- Jan 10, 2017
- Penalty
- Initial $2,138 · Current $1,497 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs: a) On December 6, 2016, an energized wall-mounted electrical control panel was not protected with a cover, exposing employees to arc flash and electrical hazards.
Recent events (2)
- — I (S) $1496.6
- — Z (S) $2138
1926.404 F06
- Issued
- Jan 10, 2017
- Penalty
- Initial $2,850 · Current $1,995 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On December 6, 2016, two extension cords hard wired into a circuit breaker panel were not connected to a grounding conductor, exposing employees to electrical and fire hazards.
Recent events (2)
- — I (S) $1995
- — Z (S) $2850
1926.501 B13
- Issued
- Jan 10, 2017
- Penalty
- Initial $2,138 · Current $1,497 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) On December 6, 2016, an employee was working on top of a one-story building on a wood roofing support beam where the roofing was completely removed, was not protected from falling to the lower level, exposing the employee to a fall hazard.
Recent events (2)
- — I (S) $1496.6
- — Z (S) $2138
More inspections in this industry (NAICS 236220)
More inspections in MP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341957371.