Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WATERROWER INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of WATERROWER INC. in 560 METACOM AVENUE, WARREN, RI 02885 (NAICS 339920). OSHA activity number 341959385.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Waterrower INC. — free Get an email when a new federal OSHA severe-injury report for Waterrower INC. is published. One employer, no account, unsubscribe in one click.
Establishment
WATERROWER INC.
Site address
560 METACOM AVENUE
City
WARREN
State
RI
ZIP
02885
Mailing
560 METACOM AVENUE, WARREN, RI 02885
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339920
Employees
150
Ownership type
A

6 citations on file for this inspection.

1910.38 B

Serious Gravity 1 1 instance 100 exposed
Issued
Mar 15, 2017
Abate by
Apr 28, 2017
Penalty
Initial $5,377 · Current $3,775 Reduced
29 CFR 1910.38(b): An emergency action plan must be in writing, kept in the workplace, and available to employees for review. However, an employer with 10 or fewer employees may communicate the plan orally to employees:    Worksite:  The employer did not develop and implement a written emergency action plan when employees use, and are exposed to, flammable liquid solvents used in wood-staining tasks and combustible powders used in electrostatic powder-coating operations.
Recent events (2)
  • — I (S) $3775
  • — Z (S) $5377

1910.107 B05 I

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 15, 2017
Abate by
Apr 28, 2017
Penalty
Initial $8,963 · Current $6,275 Reduced
29 CFR 1910.107(b)(5)(i): Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. :    Spray Booth Area: The electrostatic spray booth did not have a velocity of at least 60 linear feet per minute across the face of the booth during electrostatic spraying processes.
Recent events (2)
  • — I (S) $6275
  • — Z (S) $8963

1910.107 B05 I

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 15, 2017
Abate by
Apr 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained:  Spray Booth Area: The electrostatic spray booth was not outfitted with visible gauges, audible alarms, or pressure activated devices to indicate or ensure that the required 60 linear feet per minute was being maintained during electrostatic spray operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 D02

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 15, 2017
Abate by
Apr 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.107(d)(2):  Spraying area(s) were not provided with mechanical ventilation adequate to remove flammable vapors, mists or powders to a safe location and to confine and control combustible residues:  Electrostatic Spray Booth area: Where powder coating operations were conducted in an electrostatic spray booth mechanical ventilation was inadequate to contain fugitive combustible powder emissions from exiting the booth.  This created a Spray Area outside of the booth, and allowed combustible powder accumulations onto adjacent, unapproved electrical equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 C02

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 15, 2017
Abate by
Apr 28, 2017
Penalty
Initial $7,172 · Current $5,025 Reduced
29 CFR 1910.107(c)(2): Open flame(s) or spark producing equipment, not separated by a partition, were located within 20 feet of spraying area(s):    Worksite: Where electrostatic spraying with combustible powders was conducted and the powder leaked outside of a spray booth, the employer did not separate the operations from adjacent spark and/or flame producing equipment by a distance of at least 20 feet, or by a suitable partition. Mechanical ventilation was inadequate to prevent fugitive combustible powder emissions from exiting the booth. This allowed space outside the booth to become a Spray Area.  In this Spray Area combustible powder accumulated onto adjacent, unapproved electrical equipment.
Recent events (2)
  • — I (S) $5025
  • — Z (S) $7172

1910.1200 E01

Deleted Serious Gravity 1 1 instance 120 exposed
Issued
Mar 15, 2017
Abate by
Apr 28, 2017
Penalty
Initial $5,378 · Current $0 Reduced
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):  Worksite: When employees work with, and are exposed to, hazardous metal-coating powders and solvent-based chemicals during the manufacturing tasks, the employer did not develop and implement a written hazard communication program that includes the requirements found in 29 CFR 1910.1200(e)(1)(i), and (e)(1)(ii).
Recent events (2)
  • — I (S) $0
  • — Z (S) $5378

View Waterrower INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341959385.