LUBBOCK, TX —
OSHA Inspection: NCI GROUP, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NCI GROUP, INC in 5711 E. FM 40, LUBBOCK, TX 79403 (NAICS 332312). OSHA activity number 341963221.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NCI GROUP, INC
- Site address
- 5711 E. FM 40
- City
- LUBBOCK
- State
- TX
- ZIP
- 79403
- Mailing
- P.O. BOX 692055, HOUSTON, TX 77269
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 50
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.184 D
- Issued
- Jun 8, 2017
- Abate by
- Jul 5, 2017
- Penalty
- Initial $9,959 · Current $0 Reduced
General-duty citation text
29 CFR 1910.184(d): Employer did not ensure that sling(s), fastenings and attachments were not inspected by a competent person each day, before being used, for damage or defects: In the shop, at least four (4) employees working the z/c line were engaged in metal work activities, using a frayed mesh sling multiple times a day to lift and move and z/c metal roofing material to semi tractor trailer where they were exposed to crushed-by and/or caught-between hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $9959
1910.184 G09 I
- Issued
- Jun 8, 2017
- Abate by
- Jul 5, 2017
- Penalty
- Initial $9,959 · Current $0 Reduced
General-duty citation text
29 CFR 1910.184(g)(9)(i): Employer did not ensure that the broken weld or broken brazed joint along the sling edge was removed from service: In the shop, at least four (4) employees working the z/c line were engaged in metal work activities, using a frayed mesh sling multiple times a day to lift and move and z/c metal roofing material to semi tractor trailer where they were exposed to crushed-by and/or caught-between hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $9959
1910.303 G01 I B
- Issued
- Jun 8, 2017
- Abate by
- Jul 15, 2017
- Penalty
- Initial $9,959 · Current $4,980 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(B): Employer did not ensure electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of the working space in front of electrical equipment was less than the width of the equipment or 762 mm (30 inches), whichever was greater: In the shop, breaker and electrical panels were blocked by other electrical equipment exposing employees to electrical shock and burn hazards: 1. Electrical shut off breaker on west wall in trim line shop was blocked by down spout machine. 2. Electrical panels on east wall north of z/c line shop was blocked by compressor. 3. Electrical panes on east wall in the z/c line area were blocked by z/c line machine.
Recent events (2)
- — I (S) $4979.5
- — Z (S) $9959
More inspections at NCI Group, INC
View NCI Group, INC's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341963221.