Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RIESTERER & SCHNELL, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RIESTERER & SCHNELL, INC. in N6701 HARRIS STREET, WESTFIELD, WI 53964 (NAICS 811310). OSHA activity number 341966570.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Riesterer & Schnell, INC. — free Get an email when a new federal OSHA severe-injury report for Riesterer & Schnell, INC. is published. One employer, no account, unsubscribe in one click.
Site address
N6701 HARRIS STREET
City
WESTFIELD
State
WI
ZIP
53964
Mailing
N2225 GREENVILLE DR., GREENVILLE, WI 54942
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
18
Ownership type
A

6 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 18 exposed
Issued
Feb 23, 2017
Abate by
Mar 23, 2017
Penalty
Initial $12,675 · Current $12,675
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  The employer did not establish an energy control program consisting of adequate energy control procedures, employee training, and periodic inspections when employees were performing servicing and maintenance work on various equipment and machines including agricultural tractors and combines on a daily basis.
Recent events (2)
  • — I (S) $12675
  • — Z (S) $12675

1910.147 C04 I

Serious Gravity 10 1 instance 18 exposed
Issued
Feb 23, 2017
Abate by
Apr 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section:    The employer did not develop, document, and utilize equipment specific energy control procedures when employees were performing servicing and maintenance work on various equipment and machines including agricultural tractors and combines on a daily basis.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 10 1 instance 18 exposed
Issued
Feb 23, 2017
Abate by
Mar 31, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:    The employer did not train employees engaged in servicing and maintenance work on the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation on various equipment and machines including agricultural tractors and combines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 F03 I

Serious Gravity 10 1 instance 18 exposed
Issued
Feb 23, 2017
Abate by
Mar 23, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3)(i): When servicing and/or maintenance is performed by a crew, craft, department or other group, they shall utilize a procedure which affords the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device.  The employer did not develop and implement written energy control procedures for employees participating in group lockout tagout when performing servicing and maintenance work on various equipment and machines including agricultural tractors and combines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 23, 2017
Abate by
Apr 15, 2017
Penalty
Initial $12,675 · Current $0 Reduced
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    On or about December 3, 2016, an employee was exposed to the caught-in hazards of an exposed rotating feed auger while cleaning a John Deere 9560 Combine located at N6701 Harris Court Westfield, WI.  The employer did not ensure employees implemented energy control application steps prior to them engaging in cleaning activities of the combine.  An employee energized a feed auger in the combine hopper while another employee attempted to clean it with compressed air while the auger was running.  The machine was not deenergized prior to the employee's engaging in the servicing/maintenance activity.    As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12675

1910.242 B

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 23, 2017
Abate by
Apr 15, 2017
Penalty
Initial $9,054 · Current $6,325 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment:    On or about December 3, 2016, employees utilized a homemade steel air wand that was not equipped with an air pressure reducer to clean combines during inspections and servicing at the N6701 Harris Court Westfield, WI 53964 location.
Recent events (2)
  • — I (S) $6325
  • — Z (S) $9054

View Riesterer & Schnell, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341966570.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.