WESTFIELD, WI —
OSHA Inspection: RIESTERER & SCHNELL, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of RIESTERER & SCHNELL, INC. in N6701 HARRIS STREET, WESTFIELD, WI 53964 (NAICS 811310). OSHA activity number 341966570.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RIESTERER & SCHNELL, INC.
- Site address
- N6701 HARRIS STREET
- City
- WESTFIELD
- State
- WI
- ZIP
- 53964
- Mailing
- N2225 GREENVILLE DR., GREENVILLE, WI 54942
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- Employees
- 18
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C01
- Issued
- Feb 23, 2017
- Abate by
- Mar 23, 2017
- Penalty
- Initial $12,675 · Current $12,675
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: The employer did not establish an energy control program consisting of adequate energy control procedures, employee training, and periodic inspections when employees were performing servicing and maintenance work on various equipment and machines including agricultural tractors and combines on a daily basis.
Recent events (2)
- — I (S) $12675
- — Z (S) $12675
1910.147 C04 I
- Issued
- Feb 23, 2017
- Abate by
- Apr 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section: The employer did not develop, document, and utilize equipment specific energy control procedures when employees were performing servicing and maintenance work on various equipment and machines including agricultural tractors and combines on a daily basis.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Feb 23, 2017
- Abate by
- Mar 31, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: The employer did not train employees engaged in servicing and maintenance work on the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation on various equipment and machines including agricultural tractors and combines.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 F03 I
- Issued
- Feb 23, 2017
- Abate by
- Mar 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(3)(i): When servicing and/or maintenance is performed by a crew, craft, department or other group, they shall utilize a procedure which affords the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device. The employer did not develop and implement written energy control procedures for employees participating in group lockout tagout when performing servicing and maintenance work on various equipment and machines including agricultural tractors and combines.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D
- Issued
- Feb 23, 2017
- Abate by
- Apr 15, 2017
- Penalty
- Initial $12,675 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about December 3, 2016, an employee was exposed to the caught-in hazards of an exposed rotating feed auger while cleaning a John Deere 9560 Combine located at N6701 Harris Court Westfield, WI. The employer did not ensure employees implemented energy control application steps prior to them engaging in cleaning activities of the combine. An employee energized a feed auger in the combine hopper while another employee attempted to clean it with compressed air while the auger was running. The machine was not deenergized prior to the employee's engaging in the servicing/maintenance activity. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $12675
1910.242 B
- Issued
- Feb 23, 2017
- Abate by
- Apr 15, 2017
- Penalty
- Initial $9,054 · Current $6,325 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment: On or about December 3, 2016, employees utilized a homemade steel air wand that was not equipped with an air pressure reducer to clean combines during inspections and servicing at the N6701 Harris Court Westfield, WI 53964 location.
Recent events (2)
- — I (S) $6325
- — Z (S) $9054
More inspections at Riesterer & Schnell, INC.
View Riesterer & Schnell, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811310)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341966570.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.