Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RAMIRO GALVAN

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of RAMIRO GALVAN in 5080 ITALIA LANE, GRAND PRAIRIE, TX 75052 (NAICS 238160). OSHA activity number 341967610.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ramiro Galvan — free Get an email when a new federal OSHA severe-injury report for Ramiro Galvan is published. One employer, no account, unsubscribe in one click.
Establishment
RAMIRO GALVAN
Site address
5080 ITALIA LANE
City
GRAND PRAIRIE
State
TX
ZIP
75052
Mailing
326 EAST ILLINOIS AVE. APT 225, DALLAS, TX 75216
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 3, 2017
Abate by
Mar 6, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  At the back of a townhome, employees performing roofing activities were working in close proximity to energized overhead power lines with no protection or insulation methods, exposing employees to electrocution, electrical shock, and/or burns.
Recent events (1)
  • — Z (S) $3803

1926.416 A03

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 3, 2017
Abate by
Mar 6, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into pysical or electrical contact with the electric power circuit:  At the back of the townhome, the employer did not determine whether the energized electric overhead power lines were located so that the roofing employees or their equipment would come into contact with the power lines, exposing employees to the hazards of electrocution, electrical shock and/or burns.
Recent events (1)
  • — Z (S) $3803

1926.1053 B12

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 3, 2017
Abate by
Mar 6, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive side rails:  At the back of the townhome, an employee was using an aluminum ladder while performing roofing activities, exposing the employee to electrical hazards such as electrocution, electrical shock, and/or burns.
Recent events (1)
  • — Z (S) $3803

1904.39 A02

Other-than-serious 1 instance 1 exposed
Issued
Feb 3, 2017
Abate by
Mar 6, 2017
Penalty
Initial $2,716 · Current $2,716
29 CFR 1904.39(a)(2): The employer did not report within twenty-four (24) hours, the in-patient hospitalization of one or more employees as the result of a work-related incident.  The employer did not report the hospitalization of an employee who was injured as the result of a workplace accident within 24 hours.
Recent events (1)
  • — Z (O) $2716

View Ramiro Galvan's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341967610.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.