Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GREENLAND COMPOSITES, INC.

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of GREENLAND COMPOSITES, INC. in 10175 WEBB WAY, FAYETTEVILLE, AR 72702 (NAICS 321918). OSHA activity number 341970606.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Greenland Composites, INC. — free Get an email when a new federal OSHA severe-injury report for Greenland Composites, INC. is published. One employer, no account, unsubscribe in one click.
Site address
10175 WEBB WAY
City
FAYETTEVILLE
State
AR
ZIP
72702
Mailing
2700 S. ARMSTRONG AVE, SUITE 2, FAYETTEVILLE, AR 72701
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
50
Ownership type
A

3 citations on file for this inspection.

1910.303 B01 II

Repeat Gravity 10 2 instances 20 exposed
Issued
Mar 31, 2017
Abate by
Apr 10, 2017
Penalty
Initial $19,520 · Current $10,000 Reduced
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:    On or about March 7, 2016, the employer exposed employees to electrical hazards from damaged cords found on:     a. The cord for a box fan in the regrind shredder #3 north of the machine workroom.    b. The miter cut off circular saw near the plug of the electric cord in the center of the machine workroom.    Greenland Composites, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.303(b)(1)(ii), which was contained in OSHA inspection number 1131364, citation number 1, item number 8a and was affirmed as a final order on July 18, 2016, with respect to a workplace located at 10175 Webb Way, Fayetteville, AR 72702.
Recent events (2)
  • — I (R) $10000
  • — Z (R) $19520

1910.305 B01 II

Repeat Gravity 10 3 instances 20 exposed
Issued
Mar 31, 2017
Abate by
Apr 10, 2017
Penalty
Initial $19,520 · Current $0 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    On or about December 7, 2016 and there prior, the employer exposed employees to electrical hazards from:    a. An unused opening on the bag massage electric switch box located on the north side of the machine workroom.    b. An unused opening on the Weight System conduit box located on the northeast side of the machine workroom.    c. The covers of the receptacles for the miter cut off saw in the center of the machine workroom that was missing  screws.     Greenland Composites, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard (1910.305(b)(1)(ii)), which was contained in OSHA inspection number 1131364, citation number 1, item number 10b and was affirmed as a final order on July 18, 2016, with respect to a workplace located at 10175 Webb Way, Fayetteville, AR 72702.
Recent events (2)
  • — I (R) $0
  • — Z (R) $19520

1910.22 D01

Other-than-serious 1 instance 50 exposed
Issued
Mar 31, 2017
Abate by
Apr 14, 2017
Penalty
Initial $782 · Current $0 Reduced
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.    On or about December 7, 2016 and there prior, the employer failed to mark the approved load limits for the overhead storage on the break room, exposing employees to struck-by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $782

View Greenland Composites, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341970606.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.